Energy consumption and thermal management have become key challenges in the design of large-scale air-cooled data centers, where perforated tiles are used together with cold and hot aisles to improve thermal management. Although building energy simulation can be used to estimate annual energy consumption of any building, its application in data centers has been very limited in open literature. In this paper, EnergyPlus was utilized to study selected important parameters about perforated tiles, which potentially affect the energy consumption and thermal management of a data center. The data center model has 1120 servers distributed in four rows of rack. The data center with various boundary conditions was investigated under a typical U.S. climate — hot and humid, in Miami, Florida. The key parameters about the temperature and the volumetric flow rate of the supply side have been extensively investigated. A multi-zone approach that resolves the hot and cold aisles was used to simulate the data center. Annual overall energy consumption were compared and analyzed. The simulation results show that energy consumption of the data center is significantly affected by the supply temperature and the system fan supply air flow rate under different conditions. In addition, an optimal supply temperature of 11.8°C, and air flow rate of 2.5 m3/s were found to be the most preferred selection for the data center model investigated.
Skip Nav Destination
ASME 2013 International Mechanical Engineering Congress and Exposition
November 15–21, 2013
San Diego, California, USA
Conference Sponsors:
- ASME
ISBN:
978-0-7918-5629-1
PROCEEDINGS PAPER
A Parametric Study of Temperature and Volumetric Flow Rate Parameters of a Data Center Using Multi-Zone Building Energy Simulation
Long Phan,
Long Phan
Florida International University, Miami, FL
Search for other works by this author on:
Cheng-Xian Lin
Cheng-Xian Lin
Florida International University, Miami, FL
Search for other works by this author on:
Long Phan
Florida International University, Miami, FL
Cheng-Xian Lin
Florida International University, Miami, FL
Paper No:
IMECE2013-66530, V06BT07A007; 10 pages
Published Online:
April 2, 2014
Citation
Phan, L, & Lin, C. "A Parametric Study of Temperature and Volumetric Flow Rate Parameters of a Data Center Using Multi-Zone Building Energy Simulation." Proceedings of the ASME 2013 International Mechanical Engineering Congress and Exposition. Volume 6B: Energy. San Diego, California, USA. November 15–21, 2013. V06BT07A007. ASME. https://doi.org/10.1115/IMECE2013-66530
Download citation file:
12
Views
0
Citations
Related Proceedings Papers
Related Articles
Viability of Dynamic Cooling Control in a Data Center
Environment
J. Electron. Packag (June,2006)
Experimental and Numerical Analysis of Data Center Pressure and Flow Fields Induced by Backward and Forward CRAH Technology
J. Electron. Packag (September,2022)
Related Chapters
Microstructure Evolution and Physics-Based Modeling
Ultrasonic Welding of Lithium-Ion Batteries
Dynamic Cool Roofing Systems
Advanced Energy Efficient Building Envelope Systems
The Localized Collocation Meshless Method (LCMM) Framework
Introduction to Finite Element, Boundary Element, and Meshless Methods: With Applications to Heat Transfer and Fluid Flow