Proceedings Papers

Proc. ASME. IMECE98, Micro-Electro-Mechanical Systems (MEMS), 11-17, November 15–20, 1998
Paper No: IMECE1998-1217
... gauges are measures of the three orthogonal components of the force applied at the center of the cross-beam. Calibration of the sensor is achieved by generating electromagnetic forces on an aluminum cross-beam that is suspended over the sensor structure. micro force sensor strain gauge...
Proceedings Papers

Proc. ASME. IMECE99, Heat Transfer: Volume 4, 65-70, November 14–19, 1999
Paper No: IMECE1999-1104
...Abstract Abstract The National Institute of Standards and Technology has developed a convective heat flux facility to allow calibration of heat flux sensors. The facility consists of a small wind tunnel that produces a two-dimensional laminar boundary layer across a heated isothermal copper...
Proceedings Papers

Proc. ASME. IMECE2019, Volume 9: Mechanics of Solids, Structures, and Fluids, V009T11A001, November 11–14, 2019
Paper No: IMECE2019-10521
... modeling approaches, the plug and spot weld, are calibrated, assessed, and compared to a more intensive approach — a “two-block” plug calibrated to multiple datasets. An optimization analysis workflow leveraging a genetic algorithm was exercised on a set of quasistatic test data where fasteners were pulled...
Proceedings Papers

Proc. ASME. IMECE2019, Volume 8: Heat Transfer and Thermal Engineering, V008T09A069, November 11–14, 2019
Paper No: IMECE2019-11374
... Abstract The accuracy of temperature probe calibration in a constant temperature bath is governed by the stability and uniformity of the bath. In the available literature, there have been efforts in designing baths with better stability and uniformity. This work is distinguished from...
Proceedings Papers

Proc. ASME. IMECE2013, Volume 13: Transportation Systems, V013T14A008, November 15–21, 2013
Paper No: IMECE2013-62943
... objective functions. The measurement is done in the IPEK-X- in-the-Loop Framework (XiL) [4], which enables a transmission assessment on the complete vehicle level. KEYWORDS: Hybrid-testing; calibration; application; validation and development environment; IPEK-X-in-the-Loop Framework (XiL); time efficient...
Proceedings Papers

Proc. ASME. IMECE2008, Volume 13: Nano-Manufacturing Technology; and Micro and Nano Systems, Parts A and B, 181-185, October 31–November 6, 2008
Paper No: IMECE2008-66561
... 24 08 2009 Sensitivities of microelctromechanical system (MEMS) accelerometers are typically measured and calibrated at final production test of packaged devices. This process typically requires expensive special automated test equipment (ATE) that can generate vibration stimulus...
Proceedings Papers

Proc. ASME. IMECE2005, Manufacturing Engineering and Materials Handling, Parts A and B, 691-697, November 5–11, 2005
Paper No: IMECE2005-81277
... reconfiguration, the control system also needs to be reconfigured to reflect the actual state of the machine. Mechanical reconfiguration also brings with it the need to verify the accuracy of the new configuration. Also discussed in the paper is the calibration methodology that ensures high production quality...
Proceedings Papers

Proc. ASME. IMECE2005, Manufacturing Engineering and Materials Handling, Parts A and B, 833-842, November 5–11, 2005
Paper No: IMECE2005-82893
... Cutting force predictions from machining process models are generally accurate to within 20% for a specific tool and work material combination over a wide range of cutting conditions when calibrations are accurately performed. The calibration implicitly assumes that the tool used in the cut has...
Proceedings Papers

Proc. ASME. IMECE2006, Materials, Nondestructive Evaluation, and Pressure Vessels and Piping, 603-610, November 5–10, 2006
Paper No: IMECE2006-14335
... Accurate calibration is required for high-precision mechanical stages used for inspection of mechanical parts. Because of the high cost involved in purchasing and maintaining Coordinate Measuring Machines (CMM), it is common that a dedicated or reconfigurable inspection machine is designed...