Measurements of segmental deformation made on papillary muscles obtained from cat, rabbit, dog and pig hearts suggest that the deformational behavior in these specimens is appreciably nonuniform both in the resting (passive) state and in the stimulated (active) state. In view of this, in the mechanical testing of papillary muscles, it is necessary to establish a minimum size of segment “sufficiently” far from the disturbing influence of end fixtures generally used to hold the specimen in the testing machine. The segment size should be large enough to average out the nonuniform aspects of deformation. Thus, the shape and size of the specimen dictated by the nonuniformities in the mechanical response, the thinness of the specimen dictated by the viability considerations and aspects of the testing machines and method dictated by the visco-elastic features of the specimen should be given due consideraton in the selection and testing of papillary muscles.
Skip Nav Destination
Article navigation
February 1980
Research Papers
Some Mechanical Considerations in the Selection and Testing of Papillary Muscles
J. G. Pinto
J. G. Pinto
Department of Mechanical Engineering, San Diego State University, San Diego, Calif, 92182
Search for other works by this author on:
J. G. Pinto
Department of Mechanical Engineering, San Diego State University, San Diego, Calif, 92182
J Biomech Eng. Feb 1980, 102(1): 62-66 (5 pages)
Published Online: February 1, 1980
Article history
Received:
August 8, 1979
Online:
June 15, 2009
Citation
Pinto, J. G. (February 1, 1980). "Some Mechanical Considerations in the Selection and Testing of Papillary Muscles." ASME. J Biomech Eng. February 1980; 102(1): 62–66. https://doi.org/10.1115/1.3138200
Download citation file:
Get Email Alerts
Cited By
Analysis of Transient Cutting Forces in Cortical Bone During Ultrasonically Assisted Cutting
J Biomech Eng (June 2025)
Related Articles
Local Versus Global Mechanical Effects of Intramural Swelling in Carotid Arteries
J Biomech Eng (April,2015)
Statistical Characterization of Ultrasonic Additive Manufacturing Ti/Al Composites
J. Eng. Mater. Technol (October,2010)
Radio-Translucent 3-Axis Mechanical Testing Rig for the Spine in Micro-CT
J Biomech Eng (December,2006)
In Vitro Dynamic Strain Behavior of the Mitral Valve Posterior Leaflet
J Biomech Eng (June,2005)
Related Proceedings Papers
Related Chapters
Introduction and Definitions
Handbook on Stiffness & Damping in Mechanical Design
Supporting Systems/Foundations
Handbook on Stiffness & Damping in Mechanical Design
Static Deformations Budget
Mechanics of Accuracy in Engineering Design of Machines and Robots Volume II: Stiffness and Metrology