A new technique has been devised for measuring the in situ tension in small ligaments. It is based on measuring the tension in an axially loaded flexible cable with pinned endpoints by deflecting the cable laterally and measuring its lateral load and deformation. Studies were performed in which nylon line and bone ligament bone preparations were placed in a materials tester and loaded in axial tension. Axial load as measured by lateral load and deformation was found to agree with the known load to within 8 percent. The method was sensitive to error in determination of ligament length, nonperpendicularity of the laterally applied load to the long axis of the ligament, and when used in situ, impingement of the ligament on a third bone causing bending. A device, consisting of an LVDT mounted to a rigid frame with its core rod connected to a load cell, was developed. The position of the core rod was controlled by a manual screw drive, and a hook on the other end of the core rod was used to deflect the ligament laterally. This device was applied to the study of tensions in five ligaments of the palmar wrist carpus, in seven cadaver specimens. Results showed that the radioscaphocapitate (RSC) and radiolunate (RL) ligaments had significantly greater tensions than the lunotriquetral (LT), the triquetrocapitate (TC), and scaphocapitate (SC) ligaments. For the four positions of the hand tested, neutral, 14 deg radial and 14 deg ulnar deviation, and 28 deg of extension, ligament tensions were found to be unaffected by position. In all positions tested, all ligaments had measurable tension, demonstrating the importance of ligaments in maintaining the integrity of the wrist carpus.
Skip Nav Destination
Article navigation
August 1993
Research Papers
A Method for Measuring Tension in Small Ligaments: An Application to the Ligaments of the Wrist Carpus
P. Kristal,
P. Kristal
Department of Mechanical Engineering, The University of Washington, Seattle, WA 98104
Search for other works by this author on:
A. F. Tencer,
A. F. Tencer
Department of Orthopaedics and Mechanical Engineering, The University of Washington, Seattle, WA 98104
Search for other works by this author on:
T. E. Trumble,
T. E. Trumble
Department of Orthopaedics, The University of Washington, Seattle, WA 98104
Search for other works by this author on:
E. North,
E. North
Department of Orthopaedics, The University of Washington, Seattle, WA 98104
Search for other works by this author on:
D. Parvin
D. Parvin
Department of Orthopaedics, The University of Washington, Seattle, WA 98104
Search for other works by this author on:
P. Kristal
Department of Mechanical Engineering, The University of Washington, Seattle, WA 98104
A. F. Tencer
Department of Orthopaedics and Mechanical Engineering, The University of Washington, Seattle, WA 98104
T. E. Trumble
Department of Orthopaedics, The University of Washington, Seattle, WA 98104
E. North
Department of Orthopaedics, The University of Washington, Seattle, WA 98104
D. Parvin
Department of Orthopaedics, The University of Washington, Seattle, WA 98104
J Biomech Eng. Aug 1993, 115(3): 218-224 (7 pages)
Published Online: August 1, 1993
Article history
Received:
January 27, 1992
Revised:
September 14, 1992
Online:
March 17, 2008
Citation
Kristal, P., Tencer, A. F., Trumble, T. E., North, E., and Parvin, D. (August 1, 1993). "A Method for Measuring Tension in Small Ligaments: An Application to the Ligaments of the Wrist Carpus." ASME. J Biomech Eng. August 1993; 115(3): 218–224. https://doi.org/10.1115/1.2895478
Download citation file:
Get Email Alerts
Related Articles
Design of a Novel Flexible Robotic Laparoscope Using a Two Degrees-of-Freedom Cable-Driven Continuum Mechanism With Major Arc Notches
J. Mechanisms Robotics (December,2023)
Roentgen Stereophotogrammetric Analysis Methods for Determining Ten Causes of Lengthening of a Soft-Tissue Anterior Cruciate Ligament Graft Construct
J Biomech Eng (August,2008)
A New Device and Method for Controlling the Load in Rabbit Medial Collateral Ligament Reconstructions
J Biomech Eng (February,1995)
Significance of nonlinearity consideration in finite element analysis for preclinical strength assessment of extramedullary femur plates
ASME J of Medical Diagnostics (January,0001)
Related Proceedings Papers
Related Chapters
Fatigue Analysis in the Connecting Rod of MF285 Tractor by Finite Element Method
International Conference on Advanced Computer Theory and Engineering, 4th (ICACTE 2011)
Basic Concepts
Design & Analysis of ASME Boiler and Pressure Vessel Components in the Creep Range
Sealant Stresses in Tension and Shear
Buildings Sealants: Materials, Properties, and Performance