The validation of two noninvasive methods for measuring the dynamic three-dimensional kinematics of the human scapula with a magnetic tracking device is presented. One method consists of simply fixing a sensor directly to the acromion and the other consists of mounting a sensor to an adjustable plastic jig that fits over the scapular spine and acromion. The concurrent validity of both methods was assessed separately by comparison with data collected simultaneously from an invasive approach in which pins were drilled directly into the scapula. The differences between bone and skin based measurements represents an estimation of skin motion artifact. The average motion pattern of each surface method was similar to that measured by the invasive technique, especially below 120 degrees of elevation. These results indicate that with careful consideration, both methods may offer reasonably accurate representations of scapular motion that may be used to study shoulder pathologies and help develop computational models.
Skip Nav Destination
Article navigation
April 2001
Technical Papers
Dynamic Measurements of Three-Dimensional Scapular Kinematics: A Validation Study
Andrew R. Karduna,
Andrew R. Karduna
Department of Rehabilitation Sciences, MCP Hahnemann University, Philadelphia, PA 19102
11
Search for other works by this author on:
Phil W. McClure,
Phil W. McClure
Department of Physical Therapy, Beaver College, Glenside, PA 19038
Search for other works by this author on:
Lori A. Michener,
Lori A. Michener
Department of Physical Therapy, Virginia Commonwealth University, Medical College of Virginia, Richmond, VA 32298
Search for other works by this author on:
Brian Sennett
Brian Sennett
Department of Orthopaedic Surgery, Hospital of the University of Pennsylvania, Philadelphia, PA 19104
Search for other works by this author on:
Andrew R. Karduna
11
Department of Rehabilitation Sciences, MCP Hahnemann University, Philadelphia, PA 19102
Phil W. McClure
Department of Physical Therapy, Beaver College, Glenside, PA 19038
Lori A. Michener
Department of Physical Therapy, Virginia Commonwealth University, Medical College of Virginia, Richmond, VA 32298
Brian Sennett
Department of Orthopaedic Surgery, Hospital of the University of Pennsylvania, Philadelphia, PA 19104
Contributed by the Bioengineering Division for publication in the JOURNAL OF BIOMECHANICAL ENGINEERING. Manuscript received by the Bioengineering Division Nov. 1998; revised manuscript received Dec. 2000. Associate Editor: M. L. Hull.
J Biomech Eng. Apr 2001, 123(2): 184-190 (7 pages)
Published Online: December 1, 2000
Article history
Received:
November 1, 1998
Revised:
December 1, 2000
Citation
Karduna, A. R., McClure, P. W., Michener, L. A., and Sennett, B. (December 1, 2000). "Dynamic Measurements of Three-Dimensional Scapular Kinematics: A Validation Study ." ASME. J Biomech Eng. April 2001; 123(2): 184–190. https://doi.org/10.1115/1.1351892
Download citation file:
Get Email Alerts
Related Articles
A New Subject-Specific Skin Correction Factor for Three-Dimensional Kinematic Analysis of the Scapula
J Biomech Eng (December,2009)
Knee Joint Secondary Motion Accuracy Improved by Quaternion-Based Optimizer With Bony Landmark Constraints
J Biomech Eng (December,2010)
Development and Validation of A C0–C7 FE Complex for Biomechanical Study
J Biomech Eng (October,2005)
Related Proceedings Papers
Related Chapters
Infinitesimal Mechanics of the PKMs
Mechanics of Accuracy in Engineering Design of Machines and Robots Volume I: Nominal Functioning and Geometric Accuracy
Automatic Tracking of Bone Motion Using Ultrasound
Skiing Trauma and Safety: Tenth Volume
G1 Type Scheme to JVL Inverse Kinematics
Robot Manipulator Redundancy Resolution