This paper introduces passive wireless telemetry based operation for high frequency acoustic sensors. The focus is on the development, fabrication, and evaluation of wireless, batteryless SAW-IDT MEMS microphones for biomedical applications. Due to the absence of batteries, the developed sensors are small and as a result of the batch manufacturing strategy are inexpensive which enables their utilization as disposable sensors. A pulse modulated surface acoustic wave interdigital transducer (SAW-IDT) based sensing strategy has been formulated. The sensing strategy relies on detecting the ac component of the acoustic pressure signal only and does not require calibration. The proposed sensing strategy has been successfully implemented on an in-house fabricated SAW-IDT sensor and a variable capacitor which mimics the impedance change of a capacitive microphone. Wireless telemetry distances of up to 5 centimeters have been achieved. A silicon MEMS microphone which will be used with the SAW-IDT device is being microfabricated and tested. The complete passive wireless sensor package will include the MEMS microphone wire-bonded on the SAW substrate and interrogated through an on-board antenna. This work on acoustic sensors breaks new ground by introducing high frequency (i.e., audio frequencies) sensor measurement utilizing SAW-IDT sensors. The developed sensors can be used for wireless monitoring of body sounds in a number of different applications, including monitoring breathing sounds in apnea patients, monitoring chest sounds after cardiac surgery, and for feedback sensing in compression (HFCC) vests used for respiratory ventilation. Another promising application is monitoring chest sounds in neonatal care units where the miniature sensors will minimize discomfort for the newborns.
Skip Nav Destination
Article navigation
November 2005
Technical Briefs
Passive Wireless MEMS Microphones for Biomedical Applications
A. S. Sezen,
A. S. Sezen
University of Minnesota
, 1100 Mechanical Engineering, 111 Church Street SE, Minneapolis, MN 55455
Search for other works by this author on:
S. Sivaramakrishnan,
S. Sivaramakrishnan
University of Minnesota
, 1100 Mechanical Engineering, 111 Church Street SE, Minneapolis, MN 55455
Search for other works by this author on:
S. Hur,
S. Hur
University of Minnesota
, 1100 Mechanical Engineering, 111 Church Street SE, Minneapolis, MN 55455
Search for other works by this author on:
R. Rajamani,
R. Rajamani
University of Minnesota
, 1100 Mechanical Engineering, 111 Church Street SE, Minneapolis, MN 55455
Search for other works by this author on:
W. Robbins,
W. Robbins
University of Minnesota
, 1100 Mechanical Engineering, 111 Church Street SE, Minneapolis, MN 55455
Search for other works by this author on:
B. J. Nelson
B. J. Nelson
University of Minnesota
, 1100 Mechanical Engineering, 111 Church Street SE, Minneapolis, MN 55455
Search for other works by this author on:
A. S. Sezen
University of Minnesota
, 1100 Mechanical Engineering, 111 Church Street SE, Minneapolis, MN 55455
S. Sivaramakrishnan
University of Minnesota
, 1100 Mechanical Engineering, 111 Church Street SE, Minneapolis, MN 55455
S. Hur
University of Minnesota
, 1100 Mechanical Engineering, 111 Church Street SE, Minneapolis, MN 55455
R. Rajamani
University of Minnesota
, 1100 Mechanical Engineering, 111 Church Street SE, Minneapolis, MN 55455
W. Robbins
University of Minnesota
, 1100 Mechanical Engineering, 111 Church Street SE, Minneapolis, MN 55455
B. J. Nelson
University of Minnesota
, 1100 Mechanical Engineering, 111 Church Street SE, Minneapolis, MN 55455J Biomech Eng. Nov 2005, 127(6): 1030-1034 (5 pages)
Published Online: July 8, 2005
Article history
Received:
April 1, 2005
Revised:
July 8, 2005
Citation
Sezen, A. S., Sivaramakrishnan, S., Hur, S., Rajamani, R., Robbins, W., and Nelson, B. J. (July 8, 2005). "Passive Wireless MEMS Microphones for Biomedical Applications." ASME. J Biomech Eng. November 2005; 127(6): 1030–1034. https://doi.org/10.1115/1.2049330
Download citation file:
Get Email Alerts
Related Articles
Application of Fiber-Optical Microphone for Thermo-Acoustic Measurements
J. Eng. Gas Turbines Power (January,2011)
Detection of Self-Stimulatory Behaviors of Children with Autism Using Wearable and Environmental Sensors
J. Med. Devices (June,2009)
Two Step Optimization of Transducer Locations in Single Input Single Output Tonal Global Active Noise Control in Enclosures
J. Vib. Acoust (December,2010)
Turbocharger Unstable Operation Diagnosis Using Vibroacoustic Measurements
J. Eng. Gas Turbines Power (October,2004)
Related Proceedings Papers
Related Chapters
Introduction and Scope
High Frequency Piezo-Composite Micromachined Ultrasound Transducer Array Technology for Biomedical Imaging
A Spectral Conversion Based Single-Channel Single-Microphone Speech Enhancement
International Conference on Computer and Electrical Engineering 4th (ICCEE 2011)
Micro Sensor Node for Real Time Indoor Temperature Monitoring
International Conference on Mechanical Engineering and Technology (ICMET-London 2011)