Finite Element (FE) models for the simulation of intact and implanted bone find their main purpose in accurately reproducing the associated mechanical behavior. FE models can be used for preclinical testing of joint replacement implants, where some biomechanical aspects are difficult, if not possible, to simulate and investigate in vitro. To predict mechanical failure or damage, the models should accurately predict stresses and strains. Commercially available synthetic femur models have been extensively used to validate finite element models, but despite the vast literature available on the characteristics of synthetic tibia, numerical and experimental validation of the intact and implant assemblies of tibia are very limited or lacking. In the current study, four FE models of synthetic tibia, intact and reconstructed, were compared against experimental bone strain data, and an overall agreement within 10% between experimental and FE strains was obtained. Finite element and experimental (strain gauge) models of intact and implanted synthetic tibia were validated based on the comparison of cortex bone strains. The study also includes the analysis carried out on standard tibial components with cemented and noncemented stems of the P.F.C Sigma Modular Knee System. The overall agreement within 10% previously established was achieved, indicating that FE models could be successfully validated. The obtained results include a statistical analysis where the root-mean-square-error values were always . FE models can successfully reproduce bone strains under most relevant acting loads upon the condylar surface of the tibia. Moreover, FE models, once properly validated, can be used for preclinical testing of tibial knee replacement, including misalignment of the implants in the proximal tibia after surgery, simulation of long-term failure according to the damage accumulation failure scenario, and other related biomechanical aspects.
Skip Nav Destination
Article navigation
October 2007
Technical Briefs
Finite Element and Experimental Cortex Strains of the Intact and Implanted Tibia
A. Completo,
A. Completo
Departamento de Engenharia Mecânica,
Universidade de Aveiro
, 3810-193 Aveiro, Portugal
Search for other works by this author on:
F. Fonseca,
F. Fonseca
Faculdade de Ciências da Saúde,
Universidade da Beira Interior
, 6201-001 Covilhã, Portugal
Search for other works by this author on:
J. A. Simões
J. A. Simões
Departamento de Engenharia Mecânica,
Universidade de Aveiro
, 3810-193 Aveiro, Portugal
Search for other works by this author on:
A. Completo
Departamento de Engenharia Mecânica,
Universidade de Aveiro
, 3810-193 Aveiro, Portugal
F. Fonseca
Faculdade de Ciências da Saúde,
Universidade da Beira Interior
, 6201-001 Covilhã, Portugal
J. A. Simões
Departamento de Engenharia Mecânica,
Universidade de Aveiro
, 3810-193 Aveiro, PortugalJ Biomech Eng. Oct 2007, 129(5): 791-797 (7 pages)
Published Online: February 22, 2007
Article history
Received:
January 8, 2007
Revised:
February 22, 2007
Citation
Completo, A., Fonseca, F., and Simões, J. A. (February 22, 2007). "Finite Element and Experimental Cortex Strains of the Intact and Implanted Tibia." ASME. J Biomech Eng. October 2007; 129(5): 791–797. https://doi.org/10.1115/1.2768382
Download citation file:
Get Email Alerts
Effect of Internal Mechanical Environment of Porous Scaffolds on Mechano-driven Bone Ingrowth: A Numerical Study
J Biomech Eng (September 2023)
In Silico Mechanical Effort Analysis of the All-On-4 Design Performed With Platform-Switching Distal Short Dental Implants
J Biomech Eng (September 2023)
Related Articles
A Biomechanical Study of Periacetabular Defects and Cement Filling
J Biomech Eng (April,2007)
An Efficient and Accurate Prediction of the Stability of Percutaneous Fixation of Acetabular Fractures With Finite Element Simulation
J Biomech Eng (September,2011)
Development and Validation of A C0–C7 FE Complex for Biomechanical Study
J Biomech Eng (October,2005)
Finite Element Modeling of Resurfacing Hip Prosthesis: Estimation of Accuracy Through Experimental Validation
J Biomech Eng (February,2010)
Related Proceedings Papers
Related Chapters
Vibration Analysis of the Seated Human Body in Vertical Direction
International Conference on Computer Technology and Development, 3rd (ICCTD 2011)
Data Tabulations
Structural Shear Joints: Analyses, Properties and Design for Repeat Loading
Novel and Efficient Mathematical and Computational Methods for the Analysis and Architecting of Ultralight Cellular Materials and their Macrostructural Responses
Advances in Computers and Information in Engineering Research, Volume 2