Usually the measurement of multi-segment foot and ankle complex kinematics is done with stationary motion capture devices which are limited to use in a gait laboratory. This study aimed to propose and validate a wearable system to measure the foot and ankle complex joint angles during gait in daily conditions, and then to investigate its suitability for clinical evaluations. The foot and ankle complex consisted of four segments (shank, hindfoot, forefoot, and toes), with an inertial measurement unit (3D gyroscopes and 3D accelerometers) attached to each segment. The angles between the four segments were calculated in the sagittal, coronal, and transverse planes using a new algorithm combining strap-down integration and detection of low-acceleration instants. To validate the joint angles measured by the wearable system, three subjects walked on a treadmill for five minutes at three different speeds. A camera-based stationary system that used a cluster of markers on each segment was used as a reference. To test the suitability of the system for clinical evaluation, the joint angle ranges were compared between a group of 10 healthy subjects and a group of 12 patients with ankle osteoarthritis, during two 50-m walking trials where the wearable system was attached to each subject. On average, over all joints and walking speeds, the RMS differences and correlation coefficients between the angular curves obtained using the wearable system and the stationary system were 1 deg and 0.93, respectively. Moreover, this system was able to detect significant alteration of foot and ankle function between the group of patients with ankle osteoarthritis and the group of healthy subjects. In conclusion, this wearable system was accurate and suitable for clinical evaluation when used to measure the multi-segment foot and ankle complex kinematics during long-distance walks in daily life conditions.
Skip Nav Destination
julien.favre@epfl.ch
xavier.crevoisier@chuv.ch
kamiar.aminian@epfl.ch
Article navigation
June 2012
Research Papers
Measurement of Multi-segment Foot Joint Angles During Gait Using a Wearable System
Julien Favre,
julien.favre@epfl.ch
Julien Favre
Laboratory of Movement Analysis and Measurement, Ecole Polytechnique Fédérale de Lausanne (EPFL), EPFL-STI-LMAM, Station 11, CH-1015 Lausanne, Switzerland
Search for other works by this author on:
Xavier Crevoisier,
xavier.crevoisier@chuv.ch
Xavier Crevoisier
Department of Orthopaedic Surgery and Traumatology,Centre Hospitalier Universitaire Vaudois and University of Lausanne (CHUV),Avenue Pierre-Decker 4,
CH-1011 Lausanne, Switzerland
Search for other works by this author on:
Kamiar Aminian
kamiar.aminian@epfl.ch
Kamiar Aminian
Laboratory of Movement Analysis and Measurement,Ecole Polytechnique Fédérale de Lausanne (EPFL),EPFL-STI-LMAM, Station 11,
CH-1015 Lausanne, Switzerland
Search for other works by this author on:
Julien Favre
Laboratory of Movement Analysis and Measurement, Ecole Polytechnique Fédérale de Lausanne (EPFL), EPFL-STI-LMAM, Station 11, CH-1015 Lausanne, Switzerland
julien.favre@epfl.ch
Xavier Crevoisier
Department of Orthopaedic Surgery and Traumatology,Centre Hospitalier Universitaire Vaudois and University of Lausanne (CHUV),Avenue Pierre-Decker 4,
CH-1011 Lausanne, Switzerland
xavier.crevoisier@chuv.ch
Kamiar Aminian
Laboratory of Movement Analysis and Measurement,Ecole Polytechnique Fédérale de Lausanne (EPFL),EPFL-STI-LMAM, Station 11,
CH-1015 Lausanne, Switzerland
kamiar.aminian@epfl.ch
J Biomech Eng. Jun 2012, 134(6): 061006 (8 pages)
Published Online: June 13, 2012
Article history
Received:
September 20, 2011
Revised:
April 15, 2012
Posted:
May 7, 2012
Published:
June 13, 2012
Online:
June 13, 2012
Citation
Rouhani, H., Favre, J., Crevoisier, X., and Aminian, K. (June 13, 2012). "Measurement of Multi-segment Foot Joint Angles During Gait Using a Wearable System." ASME. J Biomech Eng. June 2012; 134(6): 061006. https://doi.org/10.1115/1.4006674
Download citation file:
Get Email Alerts
Cited By
Related Articles
Hybrid Low-Cost Approach for Quadrotor Attitude Estimation
J. Comput. Nonlinear Dynam (May,2015)
The Effect of Kinematic and Kinetic Changes on Meniscal Strains During Gait
J Biomech Eng (January,2011)
Comparative Assessment of Bone Pose Estimation Using Point Cluster Technique and OpenSim
J Biomech Eng (November,2011)
Production Line Calibration for Sensors on Actively Controlled Bullets
J. Manuf. Sci. Eng (May,2004)
Related Proceedings Papers
Related Chapters
4-Bit Pipeline ADC for Monolithic Active Pixel Sensors
International Conference on Advanced Computer Theory and Engineering (ICACTE 2009)
A Digital-to-Analog Converter for Extreme Environments
Intelligent Engineering Systems through Artificial Neural Networks, Volume 16
The Design and Implement of Remote Inclinometer for Power Towers Based on MXA2500G/GSM
International Conference on Mechanical and Electrical Technology, 3rd, (ICMET-China 2011), Volumes 1–3