When optical motion capture is used for motion analysis, reflective markers or a digitizer are typically used to record the location of anatomical landmarks identified through palpation. The landmarks are then used to construct anatomical coordinate systems. Failure to consistently identify landmarks through palpation over repeat tests creates artifacts in the kinematic waveforms. The purpose of this work was to improve intra- and inter-rater reliability in determining lower limb anatomical landmarks and the associated anatomical coordinate systems using a marker alignment device (MAD). The device aids the subject in recreating the same standing posture over multiple tests, and recreates the anatomical landmarks from previous static calibration trials. We tested three different raters who identified landmarks on eleven subjects. The subjects performed walking trials and their gait kinematics were analyzed with and without the device. Ankle kinematics were not improved by the device suggesting manual palpation over repeat visits is just as effective as the MAD. Intra-class correlation coefficients between gait kinematics registered to the reference static trial and registered to follow-up static trials with and without the device were improved between 1% and 33% when the device was used. Importantly, out-of-plane hip and knee kinematics showed the greatest improvements in repeatability. These results suggest that the device is well suited to reducing palpation artifact during repeat visits to the gait lab.
Skip Nav Destination
Article navigation
April 2018
Research-Article
Operator Bias Errors Are Reduced Using Standing Marker Alignment Device for Repeated Visit Studies
Laura Hutchinson,
Laura Hutchinson
Department of Mechanical
and Materials Engineering,
Human Mobility Research Centre,
Queen's University Kingston,
130 Stuart Street,
Kingston, ON K7 L 3N6, Canada
e-mail: laura.hutchinson@queensu.ca
and Materials Engineering,
Human Mobility Research Centre,
Queen's University Kingston,
130 Stuart Street,
Kingston, ON K7 L 3N6, Canada
e-mail: laura.hutchinson@queensu.ca
Search for other works by this author on:
Amy M. Morton,
Amy M. Morton
Department of Mechanical
and Materials Engineering,
Human Mobility Research Centre,
Queen's University Kingston,
Kingston, ON K7 L 3N6, Canada
e-mail: amy_morton1@brown.edu
and Materials Engineering,
Human Mobility Research Centre,
Queen's University Kingston,
130 Stuart Street
,Kingston, ON K7 L 3N6, Canada
e-mail: amy_morton1@brown.edu
Search for other works by this author on:
Irene S. Davis,
Irene S. Davis
Spaulding National Running Centre,
Harvard Medical School,
Spaulding-Cambridge Outpatient Center,
Cambridge, MA 02138
e-mail: mcclay@udel.edu
Harvard Medical School,
Spaulding-Cambridge Outpatient Center,
1575 Cambridge Street
,Cambridge, MA 02138
e-mail: mcclay@udel.edu
Search for other works by this author on:
Kevin J. Deluzio,
Kevin J. Deluzio
Department of Mechanical
and Materials Engineering,
Human Mobility Research Centre,
Queen's University Kingston,
Kingston, ON K7 L 3N6, Canada
e-mail: kevin.deluzio@queensu.ca
and Materials Engineering,
Human Mobility Research Centre,
Queen's University Kingston,
130 Stuart Street
,Kingston, ON K7 L 3N6, Canada
e-mail: kevin.deluzio@queensu.ca
Search for other works by this author on:
Michael J. Rainbow
Michael J. Rainbow
Department of Mechanical
and Materials Engineering,
Human Mobility Research Centre,
Queen's University Kingston,
Kingston, ON K7 L 3N6, Canada
e-mail: michael.rainbow@queensu.ca
and Materials Engineering,
Human Mobility Research Centre,
Queen's University Kingston,
130 Stuart Street
,Kingston, ON K7 L 3N6, Canada
e-mail: michael.rainbow@queensu.ca
Search for other works by this author on:
Laura Hutchinson
Department of Mechanical
and Materials Engineering,
Human Mobility Research Centre,
Queen's University Kingston,
130 Stuart Street,
Kingston, ON K7 L 3N6, Canada
e-mail: laura.hutchinson@queensu.ca
and Materials Engineering,
Human Mobility Research Centre,
Queen's University Kingston,
130 Stuart Street,
Kingston, ON K7 L 3N6, Canada
e-mail: laura.hutchinson@queensu.ca
Joel B. Schwartz
Amy M. Morton
Department of Mechanical
and Materials Engineering,
Human Mobility Research Centre,
Queen's University Kingston,
Kingston, ON K7 L 3N6, Canada
e-mail: amy_morton1@brown.edu
and Materials Engineering,
Human Mobility Research Centre,
Queen's University Kingston,
130 Stuart Street
,Kingston, ON K7 L 3N6, Canada
e-mail: amy_morton1@brown.edu
Irene S. Davis
Spaulding National Running Centre,
Harvard Medical School,
Spaulding-Cambridge Outpatient Center,
Cambridge, MA 02138
e-mail: mcclay@udel.edu
Harvard Medical School,
Spaulding-Cambridge Outpatient Center,
1575 Cambridge Street
,Cambridge, MA 02138
e-mail: mcclay@udel.edu
Kevin J. Deluzio
Department of Mechanical
and Materials Engineering,
Human Mobility Research Centre,
Queen's University Kingston,
Kingston, ON K7 L 3N6, Canada
e-mail: kevin.deluzio@queensu.ca
and Materials Engineering,
Human Mobility Research Centre,
Queen's University Kingston,
130 Stuart Street
,Kingston, ON K7 L 3N6, Canada
e-mail: kevin.deluzio@queensu.ca
Michael J. Rainbow
Department of Mechanical
and Materials Engineering,
Human Mobility Research Centre,
Queen's University Kingston,
Kingston, ON K7 L 3N6, Canada
e-mail: michael.rainbow@queensu.ca
and Materials Engineering,
Human Mobility Research Centre,
Queen's University Kingston,
130 Stuart Street
,Kingston, ON K7 L 3N6, Canada
e-mail: michael.rainbow@queensu.ca
1Corresponding author.
Manuscript received April 25, 2017; final manuscript received October 28, 2017; published online January 19, 2018. Assoc. Editor: Pasquale Vena.
J Biomech Eng. Apr 2018, 140(4): 041001 (7 pages)
Published Online: January 19, 2018
Article history
Received:
April 25, 2017
Revised:
October 28, 2017
Citation
Hutchinson, L., Schwartz, J. B., Morton, A. M., Davis, I. S., Deluzio, K. J., and Rainbow, M. J. (January 19, 2018). "Operator Bias Errors Are Reduced Using Standing Marker Alignment Device for Repeated Visit Studies." ASME. J Biomech Eng. April 2018; 140(4): 041001. https://doi.org/10.1115/1.4038358
Download citation file:
Get Email Alerts
Cited By
Optimal Control Formulation for Manual Wheelchair Locomotion Simulations: Influence of Anteroposterior Stability
J Biomech Eng (November 2023)
Related Articles
The Effects of Helmet Weight on Hybrid III Head and Neck Responses by Comparing Unhelmeted and Helmeted Impacts
J Biomech Eng (October,2016)
A New Approach to Determine Ligament Strain Using Polydimethylsiloxane Strain Gauges: Exemplary Measurements of the Anterolateral Ligament
J Biomech Eng (December,2014)
2016 Editors' Choice Papers
J Biomech Eng (February,2017)
A Reconfigurable Multiplanar In Vitro Simulator for Real-Time Absolute Motion With External and Musculotendon Forces
J Biomech Eng (December,2017)
Related Proceedings Papers
Related Chapters
A Vision-Based Kinematic Calibration for Pick-and-Place Robot
International Conference on Information Technology and Management Engineering (ITME 2011)
Analysis the Effect of IMU Calibration Errors on SINS/GPS Integration Accuracy for Airborne Earth Observation
International Symposium on Information Engineering and Electronic Commerce, 3rd (IEEC 2011)
4-Bit Pipeline ADC for Monolithic Active Pixel Sensors
International Conference on Advanced Computer Theory and Engineering (ICACTE 2009)