Skip Nav Destination
Close Modal
Update search
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
NARROW
Format
Article Type
Subject Area
Topics
Date
Availability
1-4 of 4
Keywords: rotation
Close
Follow your search
Access your saved searches in your account
Would you like to receive an alert when new items match your search?
Sort by
Journal Articles
Journal:
Journal of Biomechanical Engineering
Publisher: ASME
Article Type: Research Papers
J Biomech Eng. January 2010, 132(1): 011009.
Published Online: December 18, 2009
...Michelle Roland; M. L. Hull; S. M. Howell The tibio-femoral joint has been mechanically approximated with two fixed kinematic axes of rotation, the longitudinal rotational (LR) axis in the tibia and the flexion-extension (FE) axis in the femur. The mechanical axis finder developed by Hollister et...
Journal Articles
Journal:
Journal of Biomechanical Engineering
Publisher: ASME
Article Type: Research Papers
J Biomech Eng. December 2007, 129(6): 855–862.
Published Online: April 30, 2007
... quantified using the Monte Carlo technique. The precisions in the translational and rotational adjustments were 1.20 mm and 0.90 deg respectively. The MR-based alignment method will allow consistent interpretation of results obtained during tibiofemoral compressive studies conducted using the apparatus...
Journal Articles
Journal:
Journal of Biomechanical Engineering
Publisher: ASME
Article Type: Technical Papers
J Biomech Eng. October 2005, 127(5): 829–837.
Published Online: May 31, 2005
... the kinematics of the phantom measured by this method to similar measurements made using a magnetic tracking system. Average differences between the two methods were measured as 2.82 mm rms for anterior∕posterior tibial position, and 2.63 deg rms for axial rotation. An inter-trial repeatability study of human...
Journal Articles
Journal:
Journal of Biomechanical Engineering
Publisher: ASME
Article Type: Technical Papers
J Biomech Eng. August 2002, 124(4): 422–431.
Published Online: July 30, 2002
... ventricles to the HSB model. A simplified skull base model (SSBV) included ventricle substitute but approximated the anterior and middle cranial fossae by a flat and slightly angled surface. The models were exposed to 7600 rad/s 2 peak angular acceleration with 6 ms pulse duration and 5 deg forced rotation...