The controlled processor has been proposed as a means of avoiding velocity bias in laser Doppler anemometry. A theoretical model is presented to show that results free of bias can be obtained if both the ratio of integral time scale to measurement time scale (integral scale data density) and the ratio of sampling time to the measurement time scale (normalized sample interval) are greater than five. Further, by separation of the integral scale data density and normalized sample interval parameters, it is shown that at any integral scale data density the controlled processor will not produce any less bias than a sample and hold processor and no more bias than the free running (unweighted) processor. In some situations it may be considered superior to the sample and hold processor as the data processing and hardware requirements are reduced without any loss of measurement accuracy. Experimental data confirming the theoretical results are also shown. Some of these data are contrary to at least one model available in the literature.
Skip Nav Destination
Article navigation
June 1991
Research Papers
Velocity Bias Associated With Laser Doppler Anemometer Controlled Processors
A. R. Winter,
A. R. Winter
Department of Mechanical Engineering, The University of Queensland, Queensland 4072, Australia
Search for other works by this author on:
L. J. W. Graham,
L. J. W. Graham
Department of Mechanical Engineering, The University of Queensland, Queensland 4072, Australia
Search for other works by this author on:
K. Bremhorst
K. Bremhorst
Department of Mechanical Engineering, The University of Queensland, Queensland 4072, Australia
Search for other works by this author on:
A. R. Winter
Department of Mechanical Engineering, The University of Queensland, Queensland 4072, Australia
L. J. W. Graham
Department of Mechanical Engineering, The University of Queensland, Queensland 4072, Australia
K. Bremhorst
Department of Mechanical Engineering, The University of Queensland, Queensland 4072, Australia
J. Fluids Eng. Jun 1991, 113(2): 250-255 (6 pages)
Published Online: June 1, 1991
Article history
Received:
April 4, 1990
Online:
May 23, 2008
Citation
Winter, A. R., Graham, L. J. W., and Bremhorst, K. (June 1, 1991). "Velocity Bias Associated With Laser Doppler Anemometer Controlled Processors." ASME. J. Fluids Eng. June 1991; 113(2): 250–255. https://doi.org/10.1115/1.2909488
Download citation file:
Get Email Alerts
Characterization of Two-Phase Wakes in an Upward Adiabatic Liquid-Gas Flow Around a Cylinder
J. Fluids Eng (August 2023)
Experimental Study of Turbulent Wake Flow Around Trapezoidal Cylinders With Varying Streamwise Aspect Ratios
J. Fluids Eng (August 2023)
Unsteady Simulation and Analysis of Energy Loss Mechanism of a Vertical Volute Pump Under Stall Conditions
J. Fluids Eng (August 2023)
Related Articles
Laser-Doppler-Velocimetry Measurements in a Cascade of Compressor Blades at Stall
J. Turbomach (January,1998)
The Measurement of Boundary Layers on a Compressor Blade in Cascade: Part 4—Flow Fields for Incidence Angles of −1.5 and −8.5 Degrees
J. Turbomach (April,1990)
Analysis of Vortical Flow Field in a Propeller Fan by LDV Measurements and LES—Part I: Three-Dimensional Vortical Flow Structures
J. Fluids Eng (December,2001)
Evaluation of Magnetic Resonance Velocimetry for Steady Flow
J Biomech Eng (November,1990)
Related Proceedings Papers
Related Chapters
Reference Method Accuracy and Precision (ReMAP): Phase I
Reference Method Accuracy and Precision (ReMAP): Phase 1 (CRTD Vol. 60)
Novel and Efficient Mathematical and Computational Methods for the Analysis and Architecting of Ultralight Cellular Materials and their Macrostructural Responses
Advances in Computers and Information in Engineering Research, Volume 2
Accuracy of an Axis
Mechanics of Accuracy in Engineering Design of Machines and Robots Volume I: Nominal Functioning and Geometric Accuracy