This paper presents measurements of vertical and horizontal distortions of a compressor frame during the days following a cold start. The distortions are measured using a laser beam directed along the back of the compressor at the level of the bearings. Laser targets attached to the frame generate voltages proportional to the vertical and horizontal displacement of the targets relative to the laser beam. Data are acquired by a microcomputer and high-speed A-to-D converter. Coherent averaging techniques reduce the influence of vibration on these readings to a tolerable level. Frame distortion readings are supplemented by temperatures measured at a number of points on the compressor frame and foundation block. Averaged signals from laser targets and thermocouples are logged by the computer every 2 min. Two sets of results are presented: one for a compressor mounted on a concrete block with a sand–cement full bed grout, the other for a compressor mounted on epoxy chocks. Data for the full bed grout unit cover a 53-h period. Data for the chock-mounted unit cover a 96-h period. Both units show some unexpected distortion transients during the first 24 h, and the magnitude of these is significantly greater for the full bed grout unit. Both units exhibit pronounced swings in frame distortion as ambient temperature changes from day to night. This daily cycling with ambient temperature, in particular, shows the need for careful interpretation of isolated readings of frame or crankshaft bearing alignment. The frame distortion and temperature data are supplemented by predictions of nominal crankshaft bending stress resulting from the observed misalignment.
Skip Nav Destination
Article navigation
October 1987
Research Papers
Reciprocating Compressor Frame Distortion During a Cold Start
A. J. Smalley
A. J. Smalley
Applied Physics Division, Southwest Research Institute, San Antonio, TX 78284
Search for other works by this author on:
A. J. Smalley
Applied Physics Division, Southwest Research Institute, San Antonio, TX 78284
J. Eng. Gas Turbines Power. Oct 1987, 109(4): 481-486 (6 pages)
Published Online: October 1, 1987
Article history
Received:
November 12, 1986
Online:
October 15, 2009
Citation
Smalley, A. J. (October 1, 1987). "Reciprocating Compressor Frame Distortion During a Cold Start." ASME. J. Eng. Gas Turbines Power. October 1987; 109(4): 481–486. https://doi.org/10.1115/1.3240067
Download citation file:
10
Views
Get Email Alerts
Cited By
Study of Injector Geometry and Parcel Injection Location on Spray Simulation of the Engine Combustion Network Spray G Injector
J. Eng. Gas Turbines Power (July 2023)
Fully Coupled Analysis of Flutter Induced Limit Cycles: Frequency Versus Time Domain Methods
J. Eng. Gas Turbines Power (July 2023)
Impact of Ignition Assistant on Combustion of Cetane 30 and 35 Jet-Fuel Blends in a Compression-Ignition Engine at Moderate Load and Speed
J. Eng. Gas Turbines Power (July 2023)
Related Articles
Laser Weld Penetration Estimation Using Temperature Measurements
J. Manuf. Sci. Eng (May,1999)
Stochastic Characterization and Models to Predict Performance Uncertainty in Photonic Packages
J. Electron. Packag (September,2007)
Experimental Validation of Metaconcrete Blast Mitigation Properties
J. Appl. Mech (March,2017)
Related Chapters
The ServoTeach Module
Precision Programming of Roving Robots: Project-Based Fundamentals of Wheeled, Legged and Hybrid Mobile Robots
Introductory Survey
Introduction to Plastics Engineering
Diamond Is a GAL's Best Friend
Hot Air Rises and Heat Sinks: Everything You Know about Cooling Electronics Is Wrong