This paper is the first of two papers that present the results of a comprehensive study of heat transfer and pressure drop in annuli with spirally fluted inner tubes for the laminar, transition, and turbulent flow regimes. To understand the underlying physical phenomena responsible for heat transfer enhancement, flow mechanisms documented elsewhere are combined with pressure drop measurements to propose friction factor correlations for the low Re range (Re < 800) and the high Re range (800 < Re < 43,500). Friction factors were found to be functions of the flute depth, pitch and angle, and the annulus radius ratio. These correlations are used in the second paper to develop Nusselt number correlations in terms of the fluted annulus friction factor. Transition in these annuli occurred in the 310 < Re < 1000 range. In Part II of this study, this early transition is shown to be responsible, in part, for significant heat transfer enhancement. Friction factor increases were typically between 1.1 and 2.0 in the laminar regime, and up to 10 in the turbulent regime. These enhancement values can be used in conjunction with heat transfer enhancement values reported in Part II to determine appropriate ranges of applicability for spirally enhanced annuli.
Skip Nav Destination
Article navigation
Research Papers
Heat Transfer and Pressure Drop Characteristics of Spirally Fluted Annuli: Part I—Hydrodynamics
S. Garimella,
S. Garimella
Mechanical and Aeronautical Engineering Department, Western Michigan University, 2076 Kohrman Hall, Kalamazoo, MI 49008
Search for other works by this author on:
R. N. Christensen
R. N. Christensen
Mechanical Engineering Department, The Ohio State University, 206 W. Eighteenth Ave., Columbus, OH 43210
Search for other works by this author on:
S. Garimella
Mechanical and Aeronautical Engineering Department, Western Michigan University, 2076 Kohrman Hall, Kalamazoo, MI 49008
R. N. Christensen
Mechanical Engineering Department, The Ohio State University, 206 W. Eighteenth Ave., Columbus, OH 43210
J. Heat Transfer. Feb 1995, 117(1): 54-60 (7 pages)
Published Online: February 1, 1995
Article history
Received:
August 1, 1993
Revised:
March 1, 1994
Online:
December 5, 2007
Citation
Garimella, S., and Christensen, R. N. (February 1, 1995). "Heat Transfer and Pressure Drop Characteristics of Spirally Fluted Annuli: Part I—Hydrodynamics." ASME. J. Heat Transfer. February 1995; 117(1): 54–60. https://doi.org/10.1115/1.2822323
Download citation file:
Get Email Alerts
Cited By
Aircraft Ducted Heat Exchanger Aerodynamic Shape and Thermal Optimization
J. Heat Mass Transfer
A Simplified Thermal Hydraulic Model for Solid Pin-Fueled Molten Salt Reactors Under Low-Flow Accident Scenarios
J. Heat Mass Transfer (December 2024)
Effect of Forced Convection Heat Transfer on Vapor Quality in Subcooled Flow Boiling
J. Heat Mass Transfer (December 2024)
Related Articles
Heat Transfer-Friction Characteristic Comparison in Rectangular Ducts With Slit and Solid Ribs Mounted on One Wall
J. Heat Transfer (August,1998)
Experimental Study of the Effect of Transverse Oscillation on Convection Heat Transfer From a Circular Cylinder
J. Heat Transfer (August,1997)
Heat Transfer and Friction in a Low-Aspect-Ratio Rectangular Channel With Staggered Perforated Ribs on Two Opposite Walls
J. Heat Transfer (November,1995)
Visualization and Analysis of Flow in an Offset Channel
J. Heat Transfer (November,1992)
Related Proceedings Papers
Related Chapters
Hydraulic Resistance
Heat Transfer & Hydraulic Resistance at Supercritical Pressures in Power Engineering Applications
Heat Transfer Enhancement by Using Nanofluids in Laminar Forced Convection Flows Considering Variable Properties
Proceedings of the 2010 International Conference on Mechanical, Industrial, and Manufacturing Technologies (MIMT 2010)
The Design and Implement of Remote Inclinometer for Power Towers Based on MXA2500G/GSM
International Conference on Mechanical and Electrical Technology, 3rd, (ICMET-China 2011), Volumes 1–3