The present paper addresses the measurement errors in temperature due to the effects of surface-mounted temperature sensors like thermocouples. Heat conduction into or from the installed thermocouple wires can alter the temperature at the thermocouple junction as well as in its immediate vicinity. As a result, the emf appearing at the thermocouple terminals does not correspond to the actual surface temperature. In this paper, we present a dual-scale computational method that can be used to calculate the transient temperatures at the multiple thermocouple junctions during heating or cooling of an object. The basis of the method is a thermocouple submodel embedded in a FEM model for the parent object. The numerical results of the dual-scale computational model are compared with that of the conventional FEM models as well as the analytical solutions available. This paper also discusses the characteristics of surface-mounted thermocouples in a range of configurations.
Skip Nav Destination
Article navigation
August 2004
Research Papers
A Dual-Scale Computational Method for Correcting Surface Temperature Measurement Errors
T. C. Tszeng,
T. C. Tszeng
Department of Mechanical, Materials and Aerospace Engineering, Illinois Institute of Technology, Chicago, IL 60616
Search for other works by this author on:
G. F. Zhou
G. F. Zhou
Department of Mechanical, Materials and Aerospace Engineering, Illinois Institute of Technology, Chicago, IL 60616
Search for other works by this author on:
T. C. Tszeng
Department of Mechanical, Materials and Aerospace Engineering, Illinois Institute of Technology, Chicago, IL 60616
G. F. Zhou
Department of Mechanical, Materials and Aerospace Engineering, Illinois Institute of Technology, Chicago, IL 60616
Contributed by the Heat Transfer Division for publication in the JOURNAL OF HEAT TRANSFER. Manuscript received by the Heat Transfer Division January 8, 2003; revision received April 20, 2004. Associate Editor: A. F. Emery.
J. Heat Transfer. Aug 2004, 126(4): 535-539 (5 pages)
Published Online: April 20, 2004
Article history
Received:
January 8, 2003
Revised:
April 20, 2004
Citation
Tszeng , T. C., and Zhou, G. F. (April 20, 2004). "A Dual-Scale Computational Method for Correcting Surface Temperature Measurement Errors ." ASME. J. Heat Transfer. August 2004; 126(4): 535–539. https://doi.org/10.1115/1.1773585
Download citation file:
Get Email Alerts
Cited By
Related Articles
Distortion in Thermal Field Around Inserted Thermocouples in Experimental Interfacial Studies, Part 4: End Effect
J. Manuf. Sci. Eng (February,2002)
Design of Micro-Temperature Sensor Array With Thin Film Thermocouples
J. Electron. Packag (September,2005)
Development of Ni Cr ∕ Ni Si Thin-Film Thermocouple Sensor for Workpiece Temperature Measurement in Chemical Explosive Material Machining
J. Manuf. Sci. Eng (February,2006)
Identification of Time-Varying Time Constants of Thermocouple Sensors and Its Application to Temperature Measurement
J. Dyn. Sys., Meas., Control (January,2009)
Related Proceedings Papers
Related Chapters
Thermotriples
Hot Air Rises and Heat Sinks: Everything You Know about Cooling Electronics Is Wrong
EVALUATION OF THERMAL PROBE COOLING EFFECT BASED ON PIPELINE PARALLEL OPTICAL CABLE
Pipeline Integrity Management Under Geohazard Conditions (PIMG)
Thermocouples: The Simplest Way to Measure Temperature Wrong
Hot Air Rises and Heat Sinks: Everything You Know about Cooling Electronics Is Wrong