In this paper transpiration cooling of a porous tube exposed to a high-temperature plasma is discussed. The plasma is generated by a high-intensity d-c arc which reaches a thermally and hydrodynamically fully developed state in the porous constrictor tube. From an energy balance over a tube cross section in this regime using a semiempirical relationship between pressure drop and mass flow rate across the porous wall, the temperature distribution in the porous material as well as local heat fluxes are determined. Properties of the porous material which are of particular importance for the performance of a transpiration-cooled arc arc determined independently. The experiments provide a check on the reliability of these data. Analytical predictions of arc and constrictor performance are compared with experimental results. A large discrepancy exists in most of the results which is mainly attributed to turbulent-flow components in the tube which, in turn, can be confirmed by other diagnostic measurements. Finally, various sources for possible errors are discussed and the limitations imposed on the performance of a transpiration-cooled arc by imperfections of porous materials and the technology involved are indicated.
Skip Nav Destination
Article navigation
Research Papers
Transpiration Cooling of the Constrictor Walls of an Electric High-Intensity Arc
J. Heberlein,
J. Heberlein
Department of Mechanical Engineering, Heat Transfer Division, University of Minnesota, Minneapolis, Minn.
Search for other works by this author on:
E. Pfender
E. Pfender
Department of Mechanical Engineering, Heat Transfer Division, University of Minnesota, Minneapolis, Minn.
Search for other works by this author on:
J. Heberlein
Department of Mechanical Engineering, Heat Transfer Division, University of Minnesota, Minneapolis, Minn.
E. Pfender
Department of Mechanical Engineering, Heat Transfer Division, University of Minnesota, Minneapolis, Minn.
J. Heat Transfer. May 1971, 93(2): 146-154 (9 pages)
Published Online: May 1, 1971
Article history
Received:
February 24, 1970
Revised:
August 20, 1970
Online:
August 11, 2010
Article
Article discussed|
View article
Connected Content
Citation
Heberlein, J., and Pfender, E. (May 1, 1971). "Transpiration Cooling of the Constrictor Walls of an Electric High-Intensity Arc." ASME. J. Heat Transfer. May 1971; 93(2): 146–154. https://doi.org/10.1115/1.3449776
Download citation file:
Get Email Alerts
Cited By
Thermal Anisotropy and Heat Flux Deviation Degree of Composites
J. Heat Mass Transfer
Reviewer's Recognition
J. Heat Mass Transfer (April 2025)
Related Articles
A Novel Way to Control Wall Temperature Distribution by Grading Blowing Rate
J. Heat Mass Transfer (March,2023)
Controlled Transpiration Cooling of the Anode in a High Intensity Arc
J. Heat Transfer (November,1973)
A Discussion of Transpiration Cooling Problems through an Analytical Solution of Local Thermal Nonequilibrium Model
J. Heat Transfer (October,2006)
On Thermodynamics of Gas-Turbine Cycles: Part 2—A Model for Expansion in Cooled Turbines
J. Eng. Gas Turbines Power (January,1986)
Related Proceedings Papers
Related Chapters
Introduction
Mechanical Blood Trauma in Circulatory-Assist Devices
The Special Characteristics of Closed-Cycle Gas Turbines
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Concluding remarks
Mechanical Blood Trauma in Circulatory-Assist Devices