Abstract

Although soft robotic assistive gloves have high potential for restoring functional independence for individuals with motor impairment, their lack of rigid components makes it difficult to obtain accurate position sensing to validate their performance. To track soft device motion, standard practice relies on costly optical motion capture techniques, which have reduced accuracy due to limitations in marker occlusion and device deformation. We propose the Instrumented Hand as a low-cost, open-source measurement tool to serve as a standard solution for acquiring joint-level position and torque measurements from magnetoresistive sensors. Shown in a case study, the Instrumented Hand can be used to validate soft wearable devices and evaluate range of motion (ROM) and torque capabilities.

References

1.
Mozaffarian
,
D.
,
Benjamin
,
E. J.
,
Go
,
A. S.
,
Arnett
,
D. K.
,
Blaha
,
M. J.
,
Cushman
,
M.
,
Das
,
S. R.
,
De Ferranti
,
S.
,
Després
,
J. P.
,
Fullerton
,
H. J.
, and
Howard
,
V. J.
,
2016
, “
Executive Summary: Heart Disease and Stroke Statistics-2016 Update: A Report From the American Heart Association
,”
Circulation
,
133
(
4
), pp.
447
454
. 10.1161/CIR.0000000000000366
2.
Roozenbeek
,
B.
,
Maas
,
A. I.
, and
Menon
,
D. K.
,
2013
, “
Changing Patterns in the Epidemiology of Traumatic Brain Injury
,”
Nat. Rev. Neurol.
,
9
(
4
), pp.
231
236
. 10.1038/nrneurol.2013.22
3.
National Spinal Cord Injury Statistical Center
,
2016
. “
Spinal Cord Injury Facts and Figures at a Glance
”.
Birmingham, AL
:
University of Alabama at Birmingham
.
4.
Yun
,
Y.
,
Dancausse
,
S.
,
Esmatloo
,
P.
,
Serrato
,
A.
,
Merring
,
C. A.
,
Agarwal
,
P.
, and
Deshpande
,
A. D.
,
2017
, “
Maestro: An EMG-Driven Assistive Hand Exoskeleton for Spinal Cord Injury Patients
,”
IEEE International Conference on Robotics and Automation (ICRA)
,
Singapore
,
May 29–June 3
,
IEEE
,
Silverspring, MD
, pp.
2904
2910
.
5.
Chu
,
C.-Y.
, and
Patterson
,
R. M.
,
2018
, “
Soft Robotic Devices for Hand Rehabilitation and Assistance: a Narrative Review
,”
J. NeuroEng. and Rehabil.
,
15
(
9
), p.
59
. 10.1186/s12984-018-0391-x
6.
Deshpande
,
A. D.
,
Xu
,
Z.
,
Weghe
,
M. J. V.
,
Brown
,
B. H.
,
Ko
,
J.
,
Chang
,
L. Y.
,
Wilkinson
,
D. D.
,
Bidic
,
S. M.
, and
Matsuoka
,
Y.
,
2013
, “
Mechanisms of the Anatomically Correct Testbed Hand
,”
IEEE ASME Trans. Mechatron.
,
18
(
1
), pp.
238
250
. 10.1109/TMECH.2011.2166801
7.
Inter IKEA Systems B.V. Handskalad
. https://www.ikea.com/us/en/catalog/products/90424146, Accessed March 30, 2019.
8.
Poseable Silicone Slender Hands. Dapper Cadaver
, https://www.dappercadaver.com/products/poseable-silicone-female-hands
9.
Chappell
,
C.
,
2012
, “
3D Printed Hand Right
,” https://www.shapeways.com/product/Z5CZ2RKLY/3d-printed-hand-right?optionId=42512474&li=marketplace,
March
30
, 2019.
10.
Yun
,
Y.
,
Agarwal
,
P.
, and
Deshpande
,
A. D.
,
2014
, “
Accurate, Robust, and Real-time Pose Estimation of Finger
,”
J. Dyn. Syst. Meas. Control
,
137
(
3
), p.
034505
. 10.1115/1.4028162
11.
Ultraleap
. “
Leap Motion Controller
,” https://www.ultraleap.com/product/leap-motion-controller/, Accessed January 20, 2020.
12.
Smeragliuolo
,
A. H.
,
Hill
,
N. J.
,
Disla
,
L.
, and
Putrino
,
D.
,
2016
, “
Validation of the Leap Motion Controller Using Markered Motion Capture Technology
,”
J. Biomech.
,
49
(
9
), pp.
1742
1750
. 10.1016/j.jbiomech.2016.04.006
13.
Tung
,
J. Y.
,
Lulic
,
T.
,
Gonzalez
,
D. A.
,
Tran
,
J.
,
Dickerson
,
C. R.
, and
Roy
,
E. A.
,
2015
, “
Evaluation of a Portable Markerless Finger Position Capture Device: Accuracy of the Leap Motion Controller in Healthy Adults
,”
Physiol. Meas.
,
36
(
5
), pp.
1025
1035
. 10.1088/0967-3334/36/5/1025
14.
Yun
,
Y.
,
Fox
,
J.
,
Sarkar
,
S.
, and
Deshpande
,
A. D.
,
2016
, “
Testbed Finger Open Source (UT_ReNeu_Archive)
,” http://mahilab.rice.edu/content/open-source-instrumented-mannequins-wearable, Accessed March 30, 2019.
15.
Yun
,
Y.
,
Agarwal
,
P.
,
Fox
,
J.
,
Madden
,
K. E.
, and
Deshpande
,
A. D.
,
2016
, “
Accurate Torque Control of Finger Joints With UT Hand Exoskeleton Through Bowden Cable SEA
,”
IEEE International Conference on Intelligent Robots and Systems (IROS)
,
Daejeon, Korea
,
Oct. 9–14
,
IEEE
,
Silverspring, MD
, pp.
390
397
.
16.
Rose
,
C. G.
,
Juzswik
,
M.
, and
O’Malley
,
M. K.
,
2018
, “
Open-Source Instrumented Mannequins For Wearable Robots
,” http://mahilab.rice.edu/content/open-source-instrumented-mannequins-wearable, Accessed March 28, 2019.
17.
Rose
,
C. G.
, and
O’Malley
,
M. K.
,
2019
, “
Hybrid Rigid-soft Hand Exoskeleton to Assist Functional Dexterity
,”
IEEE Robot. Autom. Lett.
,
4
(
1
), pp.
73
80
. 10.1109/LRA.2018.2878931
18.
Hume
,
M. C.
,
Gellman
,
H.
,
McKellop
,
H.
, and
Brumfield Jr
,
R. H.
,
1990
, “
Functional Range of Motion of the Joints of the Hand
,”
J. Hand Surg.
,
15
(
2
), pp.
240
243
. 10.1016/0363-5023(90)90102-W
19.
Rohling
,
R. N.
, and
Hollerbach
,
J. M.
,
1993
, “
Calibrating the Human Hand for Haptic Interfaces
,”
Presence: Teleoperators Virtual Environ.
,
2
(
4
), pp.
281
296
. 10.1162/pres.1993.2.4.281
20.
Griffin
,
W. B.
,
Findley
,
R. P.
,
Turner
,
M. L.
, and
Cutkosky
,
M. R.
,
2000
, “
Calibration and Mapping of a Human Hand for Dexterous Telemanipulation
,”
Haptic Interfaces for Virtual Environments and Teleoperator Systems Symposium, ASME IMECE 2000 Conference
,
Orlando, FL
,
Nov. 5–10
,
ASME
,
New York
.
21.
Kang
,
B. B.
,
Lee
,
H.
,
In
,
H.
,
Jeong
,
U.
,
Chung
,
J.
, and
Cho
,
K.-J.
,
2016
, “
Development of a Polymer-based Tendon-driven Wearable Robotic Hand
,”
International Conference on Robotics and Automation (ICRA)
,
Stockholm, Sweden
,
May 16–21
,
IEEE
,
Silverspring, MD
, pp.
3750
3755
.
22.
In
,
H.
,
Kang
,
B. B.
,
Sin
,
M.
, and
Cho
,
K.-J.
,
2015
, “
Exo-glove: A Wearable Robot for the Hand With a Soft Tendon Routing System
,”
IEEE Robot. Autom. Mag.
,
22
(
1
), pp.
97
105
. 10.1109/MRA.2014.2362863
23.
Xiloyannis
,
M.
,
Cappello
,
L.
,
Khanh
,
D. B.
,
Yen
,
S.-C.
, and
Masia
,
L.
,
2016
, “
Modelling and Design of a Synergy-based Actuator for a Tendon-driven Soft Robotic Glove
,”
International Conference on Biomedical Robotics and Biomechatronics (BioRob)
,
Singapore
,
June 26–29
, pp.
1213
1219
.
24.
Xiloyannis
,
M.
,
Cappello
,
L.
,
Binh
,
K. D.
,
Antuvan
,
C. W.
, and
Masia
,
L.
,
2017
, “
Preliminary Design and Control of a Soft Exosuit for Assisting Elbow Movements and Hand Grasping in Activities of Daily Living
,”
J. Rehabil. Assist. Technol. Eng.
,
4
(
1
), p.
205566831668031
. 10.1177/2055668316680315
25.
Ochoa
,
J. M.
,
Yicheng
,
J.
,
Narasimhan
,
D.
, and
Kamper
,
D. G.
,
2009
, “
Development of a Portable Actuated Orthotic Glove to Facilitate Gross Extension of the Digits for Therapeutic Training After Stroke
,”
Annual International Conference of Engineering in Medicine and Biology Society
,
Minneapolis, MN
,
Sept. 2–6
,
IEEE
,
Silverspring, MD
.
26.
Pezent
,
E.
, and
McDonald
,
C. G.
,
2019
, “
Github — mahilab/MEL: Mechatronics Engine & Library
,” https://github.com/mahilab/MEL, Accessed January 18, 2019.
You do not currently have access to this content.