Nasal septal deviation occurs in approximately 20% of the population (Blaugrand, S., 1989, “The Nasal Septum and Concha Bullosa,” Otolaryngol. Clin. North Am., 22, pp. 291–306). Depending on the severity of the deviation, the natural flow of air through the nasal passages can be obstructed, possibly leading to more advanced complications such as epistaxis, rhinorrhoea, postnasal drip, recurrent sinus pain, chronic nasal obstruction, obstructive sleep apnea, and increased risk of viral or bacterial infections. Numerous measurement techniques exist to assess nasal patency and identify any nasal occlusion including deviated septums such as Computed Tomography (CT) and Magnetic Resonance Imaging (MRI) scans. However, there is no cost effective, user friendly method that attempts to measure the thickness of the septum. The design, fabrication, and operation of an easy-to-use and inexpensive device, which can be used quickly to measure nasal septal thickness post surgery and in follow up appointments is described. The device enables physicians to efficiently build a database of measures that can yield a new understanding of surgery effects. Measurements obtained using the new device are presented for five patients undergoing septoplasty surgery. It proved to be a fast and economical way to determine septal thickness. Initial results taken in pre, intra, and post surgery yielded results confirming the efficacy of the device as an efficient evaluation tool capable of giving instantaneous results of nasal septum geometry. The device achieves its intended function while keeping the product cost low. Early results also showed the efficacy in obtaining data on septoplasty surgery efficacy and septal swelling as a result of external factors such as histamines.
Skip Nav Destination
Article navigation
December 2013
Research-Article
Design of a Nasal Septum Measurement Device
Valmiki K. Sooklal,
Michael C. Larson
Michael C. Larson
e-mail: mlarson@uccs.edu
Department of Mechanical Engineering,
Department of Mechanical Engineering,
University of Colorado at Colorado Springs
,1420 Austin Bluffs Pkwy
,Colorado Springs, CO 80918
Search for other works by this author on:
Valmiki K. Sooklal
e-mail: vsooklal@eas.uccs.edu
Luke Hooper
e-mail: luke.hooper@gmail.com
Michael C. Larson
e-mail: mlarson@uccs.edu
Department of Mechanical Engineering,
Department of Mechanical Engineering,
University of Colorado at Colorado Springs
,1420 Austin Bluffs Pkwy
,Colorado Springs, CO 80918
Manuscript received June 4, 2010; final manuscript received May 11, 2011; published online September 24, 2013. Assoc. Editor: Just L. Herder.
J. Med. Devices. Dec 2013, 7(4): 041001 (7 pages)
Published Online: September 24, 2013
Article history
Received:
June 4, 2010
Revision Received:
May 11, 2011
Citation
Sooklal, V. K., Hooper, L., and Larson, M. C. (September 24, 2013). "Design of a Nasal Septum Measurement Device." ASME. J. Med. Devices. December 2013; 7(4): 041001. https://doi.org/10.1115/1.4025095
Download citation file:
78
Views
Get Email Alerts
Cited By
Related Articles
Design of a Multifunctional Forceps for Use in Endoscopic Surgery
J. Med. Devices (June,2010)
Introduction
J. Med. Devices (June,2011)
Editorial
J. Med. Devices (March,2007)
Harmonic Focus Case Study: Leading Innovation Through Unique User Research Methods and Tools
J. Med. Devices (June,2009)
Related Proceedings Papers
Related Chapters
Effects of Design and Screw Torque on Stresses in Spinal and Fracture Fixation Plates: A Photoelastic Study
Clinical and Laboratory Performance of Bone Plates
Spherical SOFM: Implications for Forensics and Craniofacial Surgery
Intelligent Engineering Systems through Artificial Neural Networks
mDFA Human Empirical Results
Modified Detrended Fluctuation Analysis (mDFA)