A novel, hand-held Reference Point Indentation (RPI) instrument, measures how well the bone of living patients and large animals resists indentation. The results presented here are reported in terms of Bone Material Strength, which is a normalized measure of how well the bone resists indentation, and is inversely related to the indentation distance into the bone. We present examples of the instrument's use in: (1) laboratory experiments on bone, including experiments through a layer of soft tissue, (2) three human clinical trials, two ongoing in Barcelona and at the Mayo Clinic, and one completed in Portland, OR, and (3) two ongoing horse clinical trials, one at Purdue University and another at Alamo Pintado Stables in California. The instrument is capable of measuring consistent values when testing through soft tissue such as skin and periosteum, and does so handheld, an improvement over previous Reference Point Indentation instruments. Measurements conducted on horses showed reproducible results when testing the horse through tissue or on bare bone. In the human clinical trials, reasonable and consistent values were obtained, suggesting the Osteoprobe® is capable of measuring Bone Material Strength in vivo, but larger studies are needed to determine the efficacy of the instrument's use in medical diagnosis.

References

1.
Ettinger
,
M. P.
,
2003
, “
Aging Bone and Osteoporosis: Strategies for Preventing Fractures in the Elderly
,”
Arch. Intern. Med.
,
163
, pp.
2237
2246
.10.1001/archinte.163.18.2237
2.
NIH
Consensus Development Panel,
2001
, “
Osteoporosis Prevention, Diagnosis, and Therapy
,”
J. Am. Med. Assoc.
,
285
, pp.
785
795
.10.1001/jama.285.6.785
3.
Rivadeneira
,
F.
,
Zillikens
,
M. C.
,
Laet
,
C. E. D.
,
Hofman
,
A.
,
Uitterlinden
,
A. G.
,
Beck
,
T. J.
, and
Pols
,
H. A.
,
2007
, “
Femoral Neck BMD is a Strong Predictor of Hip Fracture Susceptibility in Elderly Men and Women Because It Detects Cortical Bone Instability
,”
J. Bone Miner. Res.
,
22
, pp.
1781
1790
.10.1359/jbmr.070712
4.
Yang
,
L.
,
Peel
,
N.
,
Clowes
,
J. A.
,
McCloskey
E. V.
, and
Eastell
,
R.
,
2009
, “
Use of DXA-Based Structural Engineering Models of the Proximal Femur to Discriminate Hip Fracture
,”
J. Bone Miner. Res.
,
24
, pp.
33
42
.10.1359/jbmr.080906
5.
Cummings
,
S. R.
,
Karpf
,
D. B.
,
Harris
,
F.
,
Genant
,
H. K.
,
Ensrud
,
K.
,
LaCroix
,
A. Z.
, and
Black
,
D. M.
,
2002
, “
Improvement in Spine Bone Density and Reduction in Risk of Vertebral Fractures During Treatment With Antiresorptive Drugs
,”
Am. J. Med.
,
112
, pp.
281
289
.10.1016/S0002-9343(01)01124-X
6.
Boutroy
,
S.
,
Rietbergen
,
B. V.
,
Sornay-Rendu
,
E.
,
Munoz
,
F.
,
Bouxsein
,
M. L.
, and
Delmas
,
P. D.
,
2008
, “
Finite Element Analysis Based on In Vivo HR-pQCT Images of the Distal Radius is Associated With Wrist Fracture in Postmenopausal Women
,”
J. Bone Miner. Res.
,
23
, pp.
392
399
.10.1359/jbmr.071108
7.
Diez-Perez
,
A.
,
Guerri
,
R.
,
Nogues
,
X.
,
Caceres
,
E.
,
Pena
,
M. J.
,
Mellibovsky
,
L.
,
Randall
,
C.
,
Bridges
,
D.
,
Weaver
,
J. C.
,
Proctor
,
A.
,
Brimer
,
D.
,
Koester
,
K. J.
,
Ritchie
,
R. O.
, and
Hansma
,
P. K.
,
2010
, “
Microindentation for In Vivo Measurement of Bone Tissue Mechanical Properties in Humans
,”
J. Bone Miner. Res.
,
25
, pp.
1877
1885
.10.1002/jbmr.73
8.
Hansma
,
P.
,
Yu
,
H.
,
Schultz
,
D.
,
Rodriguez
,
A.
,
Yurtsev
,
E. A.
,
Orr
,
J.
,
Tang
,
S.
,
Miller
,
J.
,
Wallace
,
J.
,
Zok
,
F.
,
Li
,
C.
,
Souza
,
R.
,
Proctor
,
A.
,
Brimer
,
D.
,
Nogues-Solan
,
X.
,
Mellbovsky
,
L.
,
Pena
,
M. J.
,
Diez-Ferrer
,
O.
,
Mathews
,
P.
,
Randall
,
C.
,
Kuo
,
A.
,
Chen
,
C.
,
Peters
,
M.
,
Kohn
,
D.
,
Buckley
,
J.
,
Li
,
X.
,
Pruitt
,
L.
,
Diez-Perez
,
A.
,
Alliston
,
T.
,
Weaver
,
V.
, and
Lotz
,
J.
,
2009
, “
Tissue Diagnostic Instrument
,”
Rev. Sci. Instrum.
,
80
, p.
054303
.10.1063/1.3127602
9.
Hansma
,
P.
,
Turner
,
P.
,
Drake
,
B.
,
Yurtsev
,
E.
,
Proctor
,
A.
,
Mathews
,
P.
,
Lulejian
,
J.
,
Randall
,
C.
,
Adams
,
J.
,
Jungmann
,
R.
,
Garza-de-Leon
,
F.
,
Fantner
,
G.
,
Mkrtchyan
,
H.
,
Pontin
,
M.
,
Weaver
,
A.
,
Brown
,
M. B.
,
Sahar
,
N.
,
Rossello
,
R.
, and
Kohn
,
D.
,
2008
, “
The Bone Diagnostic Instrument II: Indentation Distance Increase
,”
Rev. Sci. Instrum.
,
79
, p.
064303
.10.1063/1.2937199
10.
Hansma
,
P. K.
,
Turner
,
P. J.
, and
Fantner
,
G. E.
,
2006
, “
Bone Diagnostic Instrument
,”
Rev. Sci. Instrum.
,
77
, p.
075105
.10.1063/1.2221506
11.
Chavassieux
,
P.
,
Seeman
,
E.
, and
Delmas
,
P. D.
,
2007
, “
Insights into Material and Structural Basis of Bone Fragility From Diseases Associated With Fractures: How Determinants of the Biomechanical Properties of Bone are Compromised by Disease
,”
Endocr. Rev.
,
28
, pp.
151
164
.10.1210/er.2006-0029
12.
Vashishth
,
D.
,
2005
, “
Age-Dependent Biomechanical Modifications in Bone
,”
Crit. Rev. Eukar. Gene.
,
15
, pp.
343
357
.10.1615/CritRevEukarGeneExpr.v15.i4.40
13.
Currey
,
J. D.
,
1979
, “
Changes in the Impact Energy Absorption of Bone With Age
,”
J. Biomech.
,
12
, pp.
459
469
.10.1016/0021-9290(79)90031-9
14.
Currey
,
J.
,
2004
, “
Incompatible Mechanical Properties in Compact Bone
,”
J. Theor. Biol.
,
231
, pp.
569
580
.10.1016/j.jtbi.2004.07.013
15.
Turner
,
C. H.
,
2002
, “
Biomechanics of Bone: Determinants of Skeletal Fragility and Bone Quality
,”
Osteop. Int.
,
13
, pp.
97
104
.10.1007/s001980200000
16.
Bouxsein
,
M. L.
,
2003
, “
Bone Quality: Where Do We Go From Here?
,”
Osteop. Int.
,
14
, pp.
S118
S127
.10.1007/s00198-003-1489-x
17.
Jepsen
,
K. J.
,
2003
, “
The Aging Cortex: To Crack or Not to Crack
,”
Osteop. Int.
,
14
, pp.
S57
S62
.10.1007/s00198-003-1475-3
18.
Seeman
,
E.
, and
Delmas
,
P. D.
,
2006
, “
Bone Quality—The Material and Structural Basis of Bone Strength and Fragility
,”
New Engl. J. Med.
,
354
, pp.
2250
2261
.10.1056/NEJMra053077
19.
Bridges
,
D.
,
Randall
,
C.
, and
Hansma
,
P.
,
2012
, “
A New Device for Performing Reference Point Indentation Without a Reference Probe
,”
Rev. Sci. Instrum.
,
83
, p.
044301
.10.1063/1.3693085
20.
Fernandez
,
R.
,
Diez-Perez
,
A.
,
Nogues
,
X.
,
Prieto-Alhambra
,
D.
,
Mellibovsky
,
L.
,
Bridges
D.
,
Randall
,
C.
, and
Hansma
,
P.
,
2011
, “
Validation of a Novel Microindenter for Bone Material Strength Measurement
,”
American Society for Bone and Mineral Research 2011 Annual Meeting
, San Diego, CA, September 16–20, http://www.asbmr.org/Meetings/AnnualMeeting/AbstractDetail.aspx?aid=cb0278aa-14cf-47e2-84be-8bf2a7e7896e
You do not currently have access to this content.