Microfluidic channels have been proposed as a method for removal of cryoprotective agents from cell suspensions [Fleming, Longmire, and Hubel, J. Biomech. Eng. 129, 703 (2007)]. The device tested consists of a rectangular cross section channel of 500 depth, 25 mm width, and 160 mm length, through which a cell suspension and wash stream flow in parallel. Cryoprotective agents diffuse from the cell stream to the wash stream and the wash stream is discarded. The washed cell stream is then ready for use. This device must be capable of removing 95% of the dimethyl sulfoxide (DMSO) from the cell stream with minimal cell losses. Our previous studies have demonstrated our ability to remove DMSO [Mata, Longmire, McKenna, Glass, and Hubel, Microfluid. Nanofluid. 5, 529 (2008)]. The next phase of the investigation involves characterizing the influence of flow conditions on cell motion through the device. To that end, Jurkat cells (lymphoblasts) in a 10% DMSO solution were flowed through the microfluidic channel in parallel with a wash stream composed of phosphate buffered saline solution (PBS). Average cell stream velocities were varied from 0.94 to 8.5 mm/s (Re 1.7 to 6.0). Cell viability at the outlet was high, indicating that cells are not damaged during their passage through the device. Gravitational settling caused an accumulation of cells near the bottom of the channel, where flow velocities are low. Cell settling leads results in an initial transient period for cell motion through the device. For the initial portion of cells flowing through the device, cells tend to accumulate in the device until a critical device population time is reached. Cell recovery (number of cells out of the device divided by the number of cells input to the device) is high (90–100%) after the device has been fully populated. For a single stage device with average cell stream velocities of mm/s, cell recovery was 90–100%. As more stages are added to the device, the population time for the device increases. Gravitational settling of cells also leads to a time-varying cell concentration from the input syringe to the inlet of the channel, as well as cell losses due to cells remaining in the horizontally-oriented syringe. Reorienting the syringes to a vertical position eliminates these losses. Cell motion within the channel can be modulated by the flow conditions used. For sufficiently high Reynolds numbers, the Segre-Silberberg effect [Segre and Silberberg, J. Fluid Mech. 14, 115 (1962)] can be used to move cells from the low velocity region of the cell stream to a higher velocity region thereby reducing the transient portion of processing the cells and improving overall recovery of cells through the device.
Skip Nav Destination
Article navigation
Design Of Medical Devices Conference Abstracts
Cell Motion in a Two-Stream Microfluidic Channel
J. Hanna,
J. Hanna
Department of Mechanical Engineering,
University of Minnesota
, 111 Church St. SE, Minneapolis, MN 55455
Search for other works by this author on:
T. B. Darr,
T. B. Darr
Department of Mechanical Engineering,
University of Minnesota
, 111 Church St. SE, Minneapolis, MN 55455
Search for other works by this author on:
A. Hubel,
A. Hubel
Department of Mechanical Engineering,
University of Minnesota
, 111 Church St. SE, Minneapolis, MN 55455
Search for other works by this author on:
C. Mata,
C. Mata
Department of Aerospace Engineering and Mechanics,
University of Minnesota
, 110 Union St. SE, Minneapolis, MN 55455
Search for other works by this author on:
E. K. Longmire,
E. K. Longmire
Department of Aerospace Engineering and Mechanics,
University of Minnesota
, 110 Union St. SE, Minneapolis, MN 55455
Search for other works by this author on:
D. H. McKenna
D. H. McKenna
Department of Laboratory Medicine and Pathology,
University of Minnesota
, 420 Delaware, Minneapolis, MN 55455
Search for other works by this author on:
J. Hanna
Department of Mechanical Engineering,
University of Minnesota
, 111 Church St. SE, Minneapolis, MN 55455
T. B. Darr
Department of Mechanical Engineering,
University of Minnesota
, 111 Church St. SE, Minneapolis, MN 55455
A. Hubel
Department of Mechanical Engineering,
University of Minnesota
, 111 Church St. SE, Minneapolis, MN 55455
C. Mata
Department of Aerospace Engineering and Mechanics,
University of Minnesota
, 110 Union St. SE, Minneapolis, MN 55455
E. K. Longmire
Department of Aerospace Engineering and Mechanics,
University of Minnesota
, 110 Union St. SE, Minneapolis, MN 55455
D. H. McKenna
Department of Laboratory Medicine and Pathology,
University of Minnesota
, 420 Delaware, Minneapolis, MN 55455J. Med. Devices. Jun 2009, 3(2): 027513 (1 pages)
Published Online: July 7, 2009
Article history
Published:
July 7, 2009
Citation
Hanna, J., Darr, T. B., Hubel, A., Mata, C., Longmire, E. K., and McKenna, D. H. (July 7, 2009). "Cell Motion in a Two-Stream Microfluidic Channel." ASME. J. Med. Devices. June 2009; 3(2): 027513. https://doi.org/10.1115/1.3135194
Download citation file:
1,377
Views
Get Email Alerts
Cited By
Related Articles
Comparison of Geometries for Diffusion-Based Extraction of Dimethyl Sulphoxide From a Cell Suspension
J. Med. Devices (June,2008)
An Innovative Rapid Thermal Cycling Device for Polymerase Chain Reaction
J. Med. Devices (June,2008)
Two-Dimensional Modeling of Nanomechanical Strains in Healthy and Diseased Single-Cells During Microfluidic Stress Applications
J. Nanotechnol. Eng. Med (May,2010)
Volumetric Stress-Strain Analysis of Optohydrodynamically Suspended Biological Cells
J Biomech Eng (January,2011)
Related Proceedings Papers
Related Chapters
Towards Real-Time Optical Measurement of Microbubble Content in Hydrodynamic Test Facilities
Proceedings of the 10th International Symposium on Cavitation (CAV2018)
LC-MS/MS on Microfluidic Device for Chloramphenicol Determination in Milk and Honey Samples Based on Molecular Imprinted Polymers
International Conference on Computer and Electrical Engineering 4th (ICCEE 2011)
Infinitesimal Mechanics of the PKMs
Mechanics of Accuracy in Engineering Design of Machines and Robots Volume I: Nominal Functioning and Geometric Accuracy