Skip Nav Destination
Close Modal
Update search
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
NARROW
Date
Availability
1-20 of 11714
Follow your search
Access your saved searches in your account
Would you like to receive an alert when new items match your search?
1
Sort by
Journal Articles
Accepted Manuscript
Journal:
Journal of Medical Devices
Publisher: ASME
Article Type: Technology Review
J. Med. Devices.
Paper No: MED-24-1183
Published Online: March 21, 2025
Journal Articles
Journal:
Journal of Medical Devices
Publisher: ASME
Article Type: Research-Article
J. Med. Devices. June 2025, 19(2): 021007.
Paper No: MED-24-1124
Published Online: March 18, 2025
Image
in Defining Anatomical Relationships of the Tibial Tubercle to Inform Execution of Tibial Tubercle Osteotomy in Revision Total Knees
> Journal of Medical Devices
Published Online: March 18, 2025
Fig. 1 Schematics illustrating the points used in tibial tuberosity measurements taken on de-identified AP and lateral view X-rays: ( a )points J and K on AP X-ray, ( b ) points A through F and lines H and I on sagittal view X-ray, and ( c ) zoomed in sagittal view X-ray with anterior measurement ... More about this image found in Schematics illustrating the points used in tibial tuberosity measurements t...
Image
in Defining Anatomical Relationships of the Tibial Tubercle to Inform Execution of Tibial Tubercle Osteotomy in Revision Total Knees
> Journal of Medical Devices
Published Online: March 18, 2025
Fig. 2 Names of measurements taken on de-identified AP and lateral view X-rays: ( a ) name of measurement taken on the AP X-ray, ( b )names of all measurements and lines seen on the lateral X-ray, and ( c ) zoomed in lateral X-ray showing measurement names in the sagittal plane. Point to point, me... More about this image found in Names of measurements taken on de-identified AP and lateral view X-rays: ( ...
Image
in Defining Anatomical Relationships of the Tibial Tubercle to Inform Execution of Tibial Tubercle Osteotomy in Revision Total Knees
> Journal of Medical Devices
Published Online: March 18, 2025
Fig. 3 Correlation between TCW and TTH; R 2 = 0.1047 More about this image found in Correlation between TCW and TTH; R 2 = 0.1047
Image
in Defining Anatomical Relationships of the Tibial Tubercle to Inform Execution of Tibial Tubercle Osteotomy in Revision Total Knees
> Journal of Medical Devices
Published Online: March 18, 2025
Fig. 4 Correlation between TCW and TTL; R 2 = 0.1648 More about this image found in Correlation between TCW and TTL; R 2 = 0.1648
Image
in Defining Anatomical Relationships of the Tibial Tubercle to Inform Execution of Tibial Tubercle Osteotomy in Revision Total Knees
> Journal of Medical Devices
Published Online: March 18, 2025
Fig. 5 Correlation between PTD and TTH; R 2 = 0.3261 More about this image found in Correlation between PTD and TTH; R 2 = 0.3261
Image
in Defining Anatomical Relationships of the Tibial Tubercle to Inform Execution of Tibial Tubercle Osteotomy in Revision Total Knees
> Journal of Medical Devices
Published Online: March 18, 2025
Fig. 6 Correlation between PTD and TTL; R 2 = 0.1775 More about this image found in Correlation between PTD and TTL; R 2 = 0.1775
Journal Articles
Journal:
Journal of Medical Devices
Publisher: ASME
Article Type: Research-Article
J. Med. Devices. June 2025, 19(2): 021008.
Paper No: MED-24-1149
Published Online: March 18, 2025
Image
in A Portable Aspiration-Assisted Device for End-Cut Prostate Biopsy of Large Tissue Sample
> Journal of Medical Devices
Published Online: March 18, 2025
Fig. 1 Limitations of current Side-Cut biopsy needle devices: ( a )biopsy core size, ( b ) no core feature delineating orientation, ( c )multiple biopsies required for adequate core, and ( e ) tissue damage beyond core sample More about this image found in Limitations of current Side-Cut biopsy needle devices: ( a )biopsy core siz...
Image
in A Portable Aspiration-Assisted Device for End-Cut Prostate Biopsy of Large Tissue Sample
> Journal of Medical Devices
Published Online: March 18, 2025
Fig. 2 Developed aspiration-assisted needle biopsy device (UF device) sample collection sequence. ( a ) The coaxial needle is inserted into the tissue. The motor and plunger holder are fixed to the device housing. ( b ) The motor is activated to move the syringe forward until it jams, which causes... More about this image found in Developed aspiration-assisted needle biopsy device (UF device) sample colle...
Image
in A Portable Aspiration-Assisted Device for End-Cut Prostate Biopsy of Large Tissue Sample
> Journal of Medical Devices
Published Online: March 18, 2025
Fig. 3 Main components housed inside the developed device (UF device) More about this image found in Main components housed inside the developed device (UF device)
Image
in A Portable Aspiration-Assisted Device for End-Cut Prostate Biopsy of Large Tissue Sample
> Journal of Medical Devices
Published Online: March 18, 2025
Fig. 4 External breadboard controller circuit More about this image found in External breadboard controller circuit
Image
in A Portable Aspiration-Assisted Device for End-Cut Prostate Biopsy of Large Tissue Sample
> Journal of Medical Devices
Published Online: March 18, 2025
Fig. 5 Modified syringe and needle components: ( a ) plunger with inner stylette, ( b ) barrel with external needle, and ( c ) full syringe and needle assembly More about this image found in Modified syringe and needle components: ( a ) plunger with inner stylette, ...
Image
in A Portable Aspiration-Assisted Device for End-Cut Prostate Biopsy of Large Tissue Sample
> Journal of Medical Devices
Published Online: March 18, 2025
Fig. 6 Biopsy devices tested: UF device (top), Bard Max-Core 1825 (middle), and Argon BioPince (bottom) More about this image found in Biopsy devices tested: UF device (top), Bard Max-Core 1825 (middle), and Ar...
Image
in A Portable Aspiration-Assisted Device for End-Cut Prostate Biopsy of Large Tissue Sample
> Journal of Medical Devices
Published Online: March 18, 2025
Fig. 7 Experimental procedure pictures: ( a ) needle insertion into gelatin specimen and ( b ) bovine cardiac tissue ex vivo More about this image found in Experimental procedure pictures: ( a ) needle insertion into gelatin specim...
Image
in A Portable Aspiration-Assisted Device for End-Cut Prostate Biopsy of Large Tissue Sample
> Journal of Medical Devices
Published Online: March 18, 2025
Fig. 8 Bar graphs of sample lengths and masses for each of the phantom tissues (G-H: 21 g gelatin, G-L: 7 g gelatin, BL: bovine liver, BK: bovine kidney, BC: bovine heart, PL: porcine liver, PK: porcine kidney, and OK: ovine kidney) for each biopsy device ( n = 1): ( a ) sample lengths and ( b ) ... More about this image found in Bar graphs of sample lengths and masses for each of the phantom tissues (G-...
Image
in A Portable Aspiration-Assisted Device for End-Cut Prostate Biopsy of Large Tissue Sample
> Journal of Medical Devices
Published Online: March 18, 2025
Fig. 9 Bovine cardiac tissue collection results. ( a ) Collected bovine cardiac tissue samples: (i) Bard Max-Core 1825 sample, (ii)Argon BioPince sample, and (iii) UF device sample. ( b ) Bar graph of average sample lengths collected using the Bard Max-Core 1825, Argon BioPince, and UF device biop... More about this image found in Bovine cardiac tissue collection results. ( a ) Collected bovine cardiac ti...
Image
in A Portable Aspiration-Assisted Device for End-Cut Prostate Biopsy of Large Tissue Sample
> Journal of Medical Devices
Published Online: March 18, 2025
Fig. 10 Samples collected using the UF device that display a ball-like structure on the distal end: ( a ) low concentration gelatin sample, ( b ) porcine liver sample, and ( c ) bovine cardiac tissue sample More about this image found in Samples collected using the UF device that display a ball-like structure on...
Journal Articles
Accepted Manuscript
Journal:
Journal of Medical Devices
Publisher: ASME
Article Type: Errata
J. Med. Devices.
Paper No: MED-25-1043
Published Online: March 17, 2025
1