Skip Nav Destination
Close Modal
Update search
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
NARROW
Format
Article Type
Subject Area
Topics
Date
Availability
1-2 of 2
Keywords: creep
Close
Follow your search
Access your saved searches in your account
Would you like to receive an alert when new items match your search?
Sort by
Journal Articles
J. W. Aebersold, W. P. Hnat, M. J. Voor, R. M. Puno, D. J. Jackson, J. T. Lin, K. M. Walsh, J. F. Naber
Journal:
Journal of Medical Devices
Publisher: ASME
Article Type: Research Papers
J. Med. Devices. June 2007, 1(2): 159–164.
Published Online: September 5, 2006
... testing system to simulate long-term implantation along with static testing to determine if creep was present. Both series of tests showed that the housing’s response did not degrade over a period of time and there was no indication of creep. The experimental results also validated the results...
Journal Articles
Niels Grabow, Carsten M. Bünger, Katrin Sternberg, Steffen Mews, Kathleen Schmohl, Klaus-Peter Schmitz
Journal:
Journal of Medical Devices
Publisher: ASME
Article Type: Technical Briefs
J. Med. Devices. March 2007, 1(1): 84–88.
Published Online: August 10, 2006
...: deployment, recoil, shortening, collapse, and creep behavior under a static load of 100 mm Hg . In vitro degradation was performed in Sørensen buffer solution at 37 ° C . After 0 ∕ 2 ∕ 4 ∕ 8 ∕ 12 ∕ 24 weeks the remaining collapse stability and molecular weight were assessed. Results: All stents could...