A new type of the reflectors for evacuated tubular collectors (ETC) which we referred to as a Compound Circular Reflector (CCR) was designed. The reflectors allow reducing the number of tubes per collector area due to increasing the center-to-center distance of tubes, i.e. the pitch of tubes, so that the weight and cost of the collectors coupled with the reflectors decrease. The reflectors also improve collector efficiency. In comparison with a collector coupled with the planar reflectors, the collector coupled with CCRs accomplished following purposes: The weight per collector area decreases by 20% and the collector efficiency increases by about 7 percentage points as well as the cost of production per collector area decreases by 33%. Therefore the cost-effectiveness of the collectors is markedly improved.

1.
Harding
,
G. L.
, and
Moon
,
T. T.
,
1981
, “
Calorimetric measurement of absorptance and emittance of the Sydney University evacuated collector
,”
Sol. Energy
,
26
, No.
4
, pp.
281
285
.
2.
Window
,
B.
, and
Zybert
,
J.
,
1981
, “
Optical collection efficiencies of arrays of tubular collectors with diffuse reflectors
,”
Sol. Energy
,
26
, No.
4
, pp.
325
331
.
3.
Chow
,
S. P.
,
Harding
,
G. L.
,
Window
,
B.
, and
Cathro
,
K. J.
,
1984
, “
Effect of collector components on the collection efficiency of tubular evacuated collectors with diffuse reflectors
,”
Sol. Energy
,
32
, No.
2
, pp.
251
262
.
4.
Chow
,
S. P.
,
Harding
,
G. L.
,
Yin
,
Z. Q.
, and
Morrison
,
G. L.
,
1984
, “
Optimization of evacuated tubular solar collector arrays with diffuse reflectors
,”
Sol. Energy
,
33
, No.
3/4
, pp.
277
282
.
5.
Hashimoto
,
T.
,
Miyatake
,
O.
,
Harada
,
T.
,
Akutagawa
,
R.
, and
Aso
,
T.
,
1984
, “
Study of a semi-circular concentrating, partially evacuated tubular solar collector
,”
JSES Journal of Solar Energy
,
10
, No.
6
, pp.
27
33
(in Japanese).
6.
Chow
,
S. P.
,
Harding
,
G. L.
, and
Cathro
,
K. J.
,
1986
, “
Optical efficiency of evacuated tubular collectors with selective surface of high solar absorptance and envelopes coated with antireflection layers
,”
Sol. Energy
,
36
, No.
3
, pp.
241
244
.
7.
Japan Quality Assurance Organization, 1993, Technical Inspection Report, Japan Quality Assurance Organization, Hamamatsu, Japan.
8.
Sando
,
M.
,
Fujii
,
A.
,
Noguchi
,
T.
, and
Toyama
,
S.
,
1984
, “
Theoretical analysis on the effective transmission-absorption factor of an evacuated tubular collector
,”
JSES Journal of Solar Energy
,
10
, No.
6
, pp.
34
40
(in Japanese).
9.
Japan Quality Assurance Organization, 1996, Technical Inspection Report, Japan Quality Assurance Organization, Hamamatsu, Japan.
10.
Zhao, C. J., and Hoshino, M., 1996, Technical Inspection Report, Shiroki Industry Corp., Fujisawa, Japan.