Lack of or improper commissioning, the inability of the building operators to grasp the complexity controls, and lack of proper maintenance lead to inefficient operations and reduced lifetimes of equipment. If regularly scheduled manual maintenance or re-commissioning practices are adopted, they can be expensive and time consuming. Automated proactive commissioning and diagnostic technologies applied to parts of the commissioning process address two of the main barriers to commissioning: cost and schedules. Automated proactive commissioning and diagnostic tools can reduce both the cost and time associated with commissioning, as well as enhance the persistence of commissioning fixes. In the long run, automation even offers the potential for automatically correcting problems by reconfiguring controls or changing control algorithms dynamically. This paper discusses procedures and processes that can be used to automate and continuously commission the economizer operation and outdoor-air ventilation systems of an air-handling unit.

1.
Portland Energy Conservation Inc. (PECI), 1997, Commissioning for Better Buildings In Oregon, Oregon Office of Energy, Salem, OR.
2.
U.S. Department of Energy/PECI. 1998, Model Commissioning Plan and Guide Commissioning Specifications, Version 2.05, PECI, Portland, OR.
3.
Claridge, D.E., Culp, C.H., Liu, M., Deng, S., Turner, W.D., and Haberl, J.S. 2000, “Campus-Wide Continuous CommissioningSM of University Buildings,” Proc. of ACEEE 2000 Summer Study on Energy Efficiency in Buildings, Pacific Grove, CA, Aug. 20-25, pp. 3.101–3.112.
4.
Katipamula, S., Pratt, R.G., and Brambley, M.R., 2003, “Methods for Automated and Continuous Commissioning of Building Systems,” in publication, PNWD-32-72, Pacific Northwest National Laboratory, Richland, Washington.
5.
Katipamula, S., Pratt, R.G., and Braun, J., 2000, Building Systems Diagnostics and Predictive Maintenance, CRC Handbook of Heating Ventilation, and Air Conditioning, Jan F. Kreider (ed.), CRC Press, New York, NY.
6.
Katipamula
,
S.
,
Pratt
,
R.G.
,
Chassin
,
D.P.
,
Taylor
,
Z.T.
,
Gowri
,
K.
, and
Brambley
,
M.R.
,
1999
, “
Automated Fault Detection and Diagnostics for Outdoor-Air Ventilation Systems and Economizers: Methodology and Results from Field Testing
,”
ASHRAE Trans.
,
105
(
1
), pp.
555
567
.
7.
Brambley
,
M.R.
,
Pratt
,
R.G.
,
Chassin
,
D.P.
, and
Katipamula
,
S.
,
1998
, “
Automated Diagnostics for Outdoor Air Ventilation and Economizers
,”
ASHRAE J.
,
40
(
10
), pp.
49
55
.
8.
Bushby, S.T, Castro, N.S., Schein, J., and House, J., 2002, Using the Virtual Cybernetic Building Testbed and FDD Test Shell for FDD Tool Development, NISTIR 6818. National Institute of Standards and Technology, Gaithersburg, MD.
9.
Croarkin, C., and Tobias, P., (ed.), 2003, Engineering Statistics Handbook, Section 2.5.5, National Institute of Standards and Technology and SEMATECH, Available at http://www.itl.nist.gov/div898/handbook/.
You do not currently have access to this content.