This paper provides an overview of research related to use of building thermal mass for shifting and reducing peak cooling loads in commercial buildings. The paper presents background on the concept and the problem of optimizing zone temperature setpoints and provides specific results that have been obtained through simulations, controlled laboratory testing, and field studies. The studies have demonstrated significant savings potential for use of building thermal mass in commercial buildings. However, the savings are sensitive to many factors, including utility rates, type of equipment, occupancy schedule, building construction, climate conditions, and control strategy. The paper also attempts to provide an assessment of the state of the art in load control using building thermal mass and to identify the steps necessary to achieve widespread application of appropriate control strategies.

1.
Braun
,
J. E.
,
1990
, “
Reducing Energy Costs and Peak Electrical Demand Through Optimal Control of Building Thermal Storage
,”
ASHRAE Trans.
,
96
(
2
), pp.
876
888
.
2.
Snyder
,
M. E.
, and
Newell
,
T. A.
,
1990
, “
Cooling Cost Minimization Using Building Mass for Thermal Storage
,”
ASHRAE Trans.
,
96
(
2
), pp.
830
838
.
3.
Keeney
,
K. R.
, and
Braun
,
J. E.
,
1996
, “
A Simplified Method for Determining Optimal Cooling Control Strategies for Thermal Storage in Building Mass
,”
International Journal of Heating, Ventilating, Air-Conditioning and Refrigerating Research
,
2
(
1
), pp.
1
20
.
4.
Chen
,
T. Y.
,
2001
, “
Real-Time Predictive Supervisory Operation of Building Thermal Systems With Thermal Mass
,”
Energy Build.
,
33
, pp.
141
150
.
5.
Nagai, T., 2002, “Optimization Method for Minimizing Annual Energy, Peak Energy Demand, and Annual Energy Cost Through Use of Building Thermal Storage,” ASHRAE Trans., 108(1).
6.
Rabl
,
A.
, and
Norford
,
L. K.
,
1991
, “
Peak Load Reduction by Preconditioning Buildings at Night
,”
Int. J. Energy Res.
,
15
, pp.
781
798
.
7.
Andresen, I., and Brandemuehl, M. J., 1992, “Heat Storage in Building Thermal Mass: A Parametric Study,” ASHRAE Trans., 98(1).
8.
Coniff
,
J. P.
,
1991
, “
Strategies for Reducing Peak Air Conditioning Loads by Using Heat Storage in the Building Structure
,”
ASHRAE Trans.
,
97
, pp.
704
709
.
9.
Morris
,
F. B.
,
Braun
,
J. E.
, and
Treado
,
S. J.
,
1994
, “
Experimental and Simulated Performance of Optimal Control of Building Thermal Storage
,”
ASHRAE Trans.
,
100
(
1
), pp.
402
414
.
10.
Andrews
,
J. W.
,
Piraino
,
M.
, and
Strasser
,
J.
,
1993
, “
Laboratory Testing of Control Strategies to Reduce Peak Air-Conditioning Loads
,”
ASHRAE Trans.
,
98
(
1
), pp.
910
918
.
11.
Braun, J. E., Lawrence, T. M., Klaassen, C. J., and House, J. M., 2002, “Demonstration of Load Shifting and Peak Load Reduction With Control of Building Thermal Mass,” Proc. of 2002 ACEEE Conf. on Energy Efficiency in Buildings, Monterey, CA.
12.
Ruud
,
M. D.
,
Mitchell
,
J. W.
, and
Klein
,
S. A.
,
1990
, “
Use of Building Thermal Mass to Offset Cooling Loads
,”
ASHRAE Trans.
,
96
(
2
), pp.
820
829
.
13.
Keeney
,
K. R.
, and
Braun
,
J. E.
,
1997
, “
Application of Building Precooling to Reduce Peak Cooling Requirements
,”
ASHRAE Trans.
,
103
(
1
), pp.
463
469
.
14.
Braun
,
J. E.
,
Montgomery
,
K. W.
, and
Chaturvedi
,
N.
,
2001
, “
Evaluating the Performance of Building Thermal Mass Control Strategies
,”
International Journal of Heating, Ventilating, Air-Conditioning and Refrigeration Research
,
7
(
4
), pp.
403
428
.
15.
Chaturvedi
,
N.
, and
Braun
,
J. E.
,
2002
, “
An Inverse Gray-Box Model for Transient Building Load Prediction
,”
International Journal of Heating, Ventilating, Air-Conditioning and Refrigeration Research
,
8
(
1
), pp.
73
100
.
You do not currently have access to this content.