In order to avoid high utility demand charges from cooling during the summer and to level a building’s electrical demand profile, precooling of the building’s massive structure can be applied to shift cooling-related thermal loads in response to utility pricing signals. Several previous simulation and experimental studies have shown that proper precooling can attain considerable reduction of operating cost in buildings. This paper systematically evaluates the merits of the passive building thermal capacitance to minimize energy cost for a design day using optimal control. The evaluation is conducted by means of a sensitivity analysis utilizing a dynamic building energy simulation program coupled to a popular technical computing environment. The optimal controller predicts the required extent of precooling (zone temperature set-point depression), depending on the utility rate structure, occupancy and on-peak period duration and onset, internal gains, building mass, occupancy period temperature set-point range, and weather as characterized by diurnal temperature and relative humidity swings. In addition to quantifying the building response, energy consumption, and utility cost, this paper extracts the dominant features of the optimal precooling strategies for each of the investigated cases so that guidelines for near-optimal building thermal mass savings may be developed in the future.
Skip Nav Destination
Article navigation
November 2007
Research Papers
Sensitivity Analysis of Optimal Building Thermal Mass Control
Gregor P. Henze,
Gregor P. Henze
Architectural Engineering,
University of Nebraska-Lincoln
, Omaha, NE 68182
Search for other works by this author on:
Thoi H. Le,
Thoi H. Le
Fraunhofer Institute for Solar Energy Systems
, D-79100 Freiburg, Germany
Search for other works by this author on:
Anthony R. Florita,
Anthony R. Florita
Architectural Engineering,
University of Nebraska-Lincoln
, Omaha, NE 68182
Search for other works by this author on:
Clemens Felsmann
Clemens Felsmann
Institute for Thermodynamics and Building Systems Engineering,
Technical University of Dresden
, D-01065 Dresden, Germany
Search for other works by this author on:
Gregor P. Henze
Architectural Engineering,
University of Nebraska-Lincoln
, Omaha, NE 68182
Thoi H. Le
Fraunhofer Institute for Solar Energy Systems
, D-79100 Freiburg, Germany
Anthony R. Florita
Architectural Engineering,
University of Nebraska-Lincoln
, Omaha, NE 68182
Clemens Felsmann
Institute for Thermodynamics and Building Systems Engineering,
Technical University of Dresden
, D-01065 Dresden, GermanyJ. Sol. Energy Eng. Nov 2007, 129(4): 473-485 (13 pages)
Published Online: May 19, 2006
Article history
Received:
May 22, 2005
Revised:
May 19, 2006
Citation
Henze, G. P., Le, T. H., Florita, A. R., and Felsmann, C. (May 19, 2006). "Sensitivity Analysis of Optimal Building Thermal Mass Control." ASME. J. Sol. Energy Eng. November 2007; 129(4): 473–485. https://doi.org/10.1115/1.2770755
Download citation file:
Get Email Alerts
Related Articles
Parametric Analysis of Active and Passive Building Thermal Storage Utilization
J. Sol. Energy Eng (February,2005)
Evaluation of Reinforcement Learning for Optimal Control of Building Active and Passive Thermal Storage Inventory
J. Sol. Energy Eng (May,2007)
Energy and Cost Minimal Control of Active and Passive Building Thermal Storage Inventory
J. Sol. Energy Eng (August,2005)
Parametric Sensitivity Analysis of Fast Load Changes of a Dynamic MCFC Model
J. Fuel Cell Sci. Technol (May,2008)
Related Proceedings Papers
Related Chapters
Modeling and Optimal Control for Batch Cooling Crystallization
International Conference on Advanced Computer Theory and Engineering, 4th (ICACTE 2011)
A Smart Sampling Strategy for One-at-a-Time Sensitivity Experiments (PSAM-0360)
Proceedings of the Eighth International Conference on Probabilistic Safety Assessment & Management (PSAM)
The Effect of Conservatism on Identifying Influential Parameters (PSAM-0381)
Proceedings of the Eighth International Conference on Probabilistic Safety Assessment & Management (PSAM)