A feasibility study of using solar liquid-desiccant air conditioner (LDAC) developed in Queensland has been undertaken. The system uses high effectiveness cross-flow polymer plate heat exchanger (PPHE), as the absorber unit. Outside air is dehumidified by strong liquid desiccant and indirectly cooled within the PPHE. The warm dry air is, subsequently, cooled and humidified through a direct evaporative cooler and supplied to the conditioned space. The weak desiccant solution from the absorber unit is concentrated in a scavenger air regenerator using hot water from flat plate solar collectors. The prototype of the absorber unit of the liquid-desiccant system has been tested under the summer conditions of Brisbane, using lithium chloride as the absorbent solution. The results of the experiments indicate that they are in good agreement with a previously developed model for the absorber unit. The tests further reveal that the unit has a satisfactory performance in controlling the air temperature and relative humidity when installed on a commercial site of 120m2 area in Brisbane. A commercialization strategy has been proposed in this study for a solar operated LDAC in Queensland and compared with the conventional direct expansion (DX) system. Based on the computer modeling results obtained from the system simulation for a building in Cairns, North Queensland, the operating costs of the LDAC are significantly lower than its conventional DX counterpart. This study further reveals that using the solar operated LDAC with a storage system will result in considerable savings in operating costs when compared with the equivalent gas-fired system. A simple payback of five years was determined for the solar components in this study.

1.
Lof
,
G. O. G
, 1955, “
Cooling With Solar Energy
,”
Congress on Solar Energy
,
Tucson, AZ
, pp.
171
189
.
2.
Lowenstein
,
A.
, 2004, “
A Solar Liquid Desiccant Air Conditioner
,” Report to the U.S. Department of Energy Under SBIR Contract.
3.
Alizadeh
,
S.
, 2002, “
Development of a Dehumidification/Indirect Evaporative Cooling System Using Liquid Desiccant
,” Ph.D. thesis, School of Advanced Manufacturing and Mechanical Engineering, the University of South Australia, Mawson Lakes Campus.
4.
Saman
,
W. Y.
, and
Alizadeh
,
S.
, 2001, “
Modelling and Performance Analysis of a Cross-Flow Type Plate Heat Exchanger for Dehumidification/Cooling
,”
Sol. Energy
0038-092X,
70
(
4
), pp.
361
372
.
5.
Alizadeh
,
S.
, and
Saman
,
W. Y.
, 2002, “
Modeling and Performance Analysis of a Forced-Flow Solar Collector/Regenerator Using Liquid Desiccant
,”
Sol. Energy
0038-092X,
72
(
2
), pp.
143
154
.
6.
Alizadeh
,
S.
, and
Saman
,
W. Y.
, 2002, “
An Experimental Study of a Forced-Flow Solar Collector/Regenerator Using Liquid Desiccant
,”
Sol. Energy
0038-092X,
73
(
5
), pp.
345
362
.
7.
Alizadeh
,
S.
, and
Khouzam
,
K.
, 2005, “
Economical and Environmental Study of a Liquid Desiccant Solar Air Conditioner for Queensland, Australia
,”
Proceedings of the ISES Solar World Congress
,
Orlando, FL
, Aug. 6–12.
8.
Alizadeh
,
S.
, and
Khouzam
,
K. Y.
, 2004, “
A Study Into the Potential of Using Liquid Desiccant Solar Air-Conditioner With Gas Backup in Brisbane—Queensland
,”
Proceedings of 42th Australian and New Zealand Solar Energy Society
,
Perth, WA
, Dec. 1–3.
9.
Saman
,
W. Y.
, and
Alizadeh
,
S.
, 2002, “
An Experimental Study of a Cross-Flow Type Plate Heat Exchanger for Dehumidification/Cooling
,”
Sol. Energy
0038-092X,
73
(
1
), pp.
59
71
.
10.
Saman
,
W. Y.
, and
Alizadeh
,
S.
, 2001, “
Design and Optimization of a Liquid Desiccant Solar Air Conditioner Using Cross Flow Type Plate Heat Exchanger
,”
ISES 2001 Solar World Congress
,
Adelaide, Australia
.
11.
Saman
,
W. Y.
, 1993, “
Developments in Evaporative and Desiccant Cooling Systems and Their Potential Application in Australia
,”
Proceedings of the Fifth Australian Heat and Mass Transfer Conference
,
Brisbane, Australia
.
12.
Farid
,
M. M.
, and
Mohammad
,
A. R.
, 1997, “
Air Dehumidification Using Liquid Desiccant
,”
CHEMECA 97
,
Rotorua, New Zealand
, Sep. 29–Oct. 1.
13.
Treybal
,
R. E.
, 1980,
Mass-Transfer Operations
,
McGaw-Hill
,
New York
.
14.
Lowenstein
,
A.
, and
Gabruk
,
R. S.
, 1992, “
The Effect of Absorber Design on the Performance of a Liquid Desiccant Air Conditioner
,”
ASHRAE Trans.
0001-2505,
98
, pp.
712
720
.
15.
McNab
,
J. L.
, and
McGregor
,
P.
, 2003, “
Dual Indirect Cycle Air Conditioner Uses Heat Concentrated Desiccant and Energy Recovery in a Polymer Plate Heat Exchanger
,”
21st IIR International Congress of Refrigeration
,
Washington, DC
, Aug. 17–22.
You do not currently have access to this content.