Abstract

An experimental and theoretical study has been performed to analyze the heat transfer and pressure drop performance of a double-pass solar air heater having arc-shaped roughness. The investigations are performed for the Reynolds number ranging from 3000 to 12,000, relative roughness pitch (p/e) ranging from 8 to 12, relative roughness height (e/d) of 0.0433, and the angle of attack (α/90) of 0.3333. The investigation has covered different performance parameters such as Nusselt number, friction factor, and thermal performance factor of rough and smooth double-pass solar air heater. A significant enhancement is observed in the heat transfer coefficient by the authors and the theoretical and experimental data are found in good agreement. The correlations for Nusselt number and friction factor are obtained for the range of parameters investigated. The maximum improvement in the Nusselt number for the rough double-pass solar air heater is obtained as 1.7 times that of the smooth double-pass solar air heater for Reynolds number of 11,283 with a relative roughness pitch of 8 and relative roughness height of 0.0433. The corresponding thermal performance factor of 1.4 is obtained for this case.

References

1.
Raj
,
P.
, and
Subudhi
,
S.
,
2018
, “
A Review of Studies Using Nanofluids in Flat-Plate and Direct Absorption Solar Collectors
,”
Renewable Sustainable Energy Rev.
,
84
, pp.
54
74
.
2.
Arora
,
S.
,
Fekadu
,
G.
, and
Subudhi
,
S.
,
2019
, “
Energy and Exergy Analysis of Marquise Shaped Channel Flat Plate Solar Collector Using Al2O3-Water Nanofluid and Water
,”
ASME J. Sol. Energy Eng.
,
141
(
4
), p.
041008
.
3.
Nowzari
,
R.
,
Saygin
,
H.
, and
Aldabbagh
,
L. B. Y.
,
2021
, “
Evaluating the Performance of a Modified Solar Air Heater With Pierced Cover and Packed Mesh Layers
,”
ASME J. Sol. Energy Eng.
,
143
(
1
), p.
011006
.
4.
Jaurker
,
A. R.
,
Saini
,
J. S.
, and
Gandhi
,
B. K.
,
2006
, “
Heat Transfer and Friction Characteristics of Rectangular Solar Air Heater Duct Using Rib-Grooved Artificial Roughness
,”
Sol. Energy
,
80
(
8
), pp.
895
907
.
5.
Moummi
,
N.
,
Youcef-Ali
,
S.
,
Moummi
,
A.
, and
Desmons
,
J. Y.
,
2004
, “
Energy Analysis of a Solar Air Collector With Rows of Fins
,”
Renewable Energy
,
29
(
13
), pp.
2053
2064
.
6.
Sharma
,
A.
,
Varun Kumar
,
P.
, and
Bharadwaj
,
G.
,
2013
, “
Heat Transfer and Friction Characteristics of Double Pass Solar Air Heater Having V-Shaped Roughness on the Absorber Plate
,”
Renewable Sustainable Energy
,
5
(
2
), p.
23109
.
7.
Singh
,
D. P.
,
Tated
,
M. K.
, and
Dogra
,
S.
,
2015
, “
Experimental Analysis of Heat Transfer and Friction Factor in Double Pass Solar Air Heater by Using Discreate Ribs on the Absorber Plate
,”
Int. J. Sci., Technol. Manage.
,
4
(
1
), pp.
677
684
.
8.
Karwa
,
R.
,
Solanki
,
S. C.
, and
Saini
,
J. S.
,
1999
, “
Heat Transfer Coefficient and Friction Factor Correlations for the Transitional Flow Regime in Rib-Roughened Rectangular Ducts
,”
Int. J. Heat Mass Transfer.
,
42
(
9
), pp.
1597
1615
.
9.
Kumar
,
R.
,
Goel
,
V.
, and
Kumar
,
A.
,
2018
, “
Investigation of Heat Transfer Augmentation and Friction Factor in Triangular Duct Solar Air Heater Due to Forward Facing Chamfered Rectangular Ribs: A CFD Based Analysis
,”
Renewable Energy
,
115
, pp.
824
835
.
10.
Aharwal
,
K. R.
,
Gandhi
,
B. K.
, and
Saini
,
J. S.
,
2008
, “
Experimental Investigation on Heat-Transfer Enhancement Due to a Gap in an Inclined Continuous Rib Arrangement in a Rectangular Duct of Solar Air Heater
,”
Renewable Energy
,
33
(
4
), pp.
585
596
.
11.
Momin
,
A.-M. E.
,
Saini
,
J. S.
, and
Solanki
,
S. C.
,
2002
, “
Heat Transfer and Friction in Solar Air Heater Duct With V-Shaped Rib Roughness on Absorber Plate
,”
Int. J. Heat Mass Transfer.
,
45
(
16
), pp.
3383
3396
.
12.
Kumar
,
A.
,
Saini
,
R. P.
, and
Saini
,
J. S.
,
2012
, “
Experimental Investigation on Heat Transfer and Fluid Flow Characteristics of Air Flow in a Rectangular Duct With Multi V-Shaped Rib with Gap Roughness on the Heated Plate
,”
Sol. Energy
,
86
(
6
), pp.
1733
1749
.
13.
Singh
,
S.
,
Chander
,
S.
, and
Saini
,
J. S.
,
2015
, “
Thermo-Hydraulic Performance Due to Relative Roughness Pitch in V-Down Rib With Gap in Solar Air Heater Duct—Comparison With Similar Rib Roughness Geometries
,”
Renewable Sustainable Energy Rev.
,
43
, pp.
1159
1166
.
14.
Deo
,
N. S.
,
Chander
,
S.
, and
Saini
,
J. S.
,
2016
, “
Performance Analysis of Solar Air Heater Duct Roughened With Multigap V-Down Ribs Combined With Staggered Ribs
,”
Renewable Energy
,
91
, pp.
484
500
.
15.
Saini
,
S. K.
, and
Saini
,
R. P.
,
2008
, “
Development of Correlations for Nusselt Number and Friction Factor for Solar Air Heater With Roughened Duct Having Arc-Shaped Wire as Artificial Roughness
,”
Sol. Energy
,
82
(
12
), pp.
1118
1130
.
16.
Singh
,
A. P.
, and
Varun
,
S.
,
2014
, “
Effect of Artificial Roughness on Heat Transfer and Friction Characteristics Having Multiple Arc Shaped Roughness Element on the Absorber Plate
,”
Sol. Energy
,
105
, pp.
479
493
.
17.
Saravanakumar
,
P. T.
,
Somasundaram
,
D.
, and
Matheswaran
,
M. M.
,
2019
, “
Thermal and Thermo-Hydraulic Analysis of Arc Shaped Rib Roughened Solar Air Heater Integrated With Fins and Baffles
,”
Sol. Energy
,
180
, pp.
360
371
.
18.
Karwa
,
R.
,
2022
, “
Enhanced Heat Transfer Performance of Multiple Triangular Air Flow Passages in Parallel With Inclined Fins for Flat Plate Solar Air Heater
,”
ASME J. Sol. Energy Eng.
,
144
(
5
), p.
051003
.
19.
Gee
,
D. L.
, and
Webb
,
R. L.
,
1980
, “
Forced Convection Heat Transfer in Helically Rib-Roughened Tubes
,”
Int. J. Heat Mass Transf.
,
23
(
8
), pp.
1127
1136
.
20.
Assari
,
M. R.
,
Basirat Tabrizi
,
H.
,
Jafari
,
I.
, and
Najafpour
,
E.
,
2014
, “
An Energy and Exergy Analysis of Water and Air With Different Passage in a Solar Collector
,”
Energy Sources, Part A Recover. Util. Environ. Eff.
,
36
(
7
), pp.
747
754
.
21.
Hans
,
V. S.
,
Saini
,
R. P.
, and
Saini
,
J. S.
,
2009
, “
Performance of Artificially Roughened Solar Air Heaters—A Review
,”
Renewable Sustainable Energy Rev.
,
13
(
8
), pp.
1854
1869
.
22.
Satcunanathan
,
S.
, and
Deonarine
,
S.
,
1973
, “
A Two-Pass Solar Air Heater
,”
Sol. Energy
,
15
(
1
), pp.
41
49
.
23.
Wijeysundera
,
N. E.
,
Ah
,
L. L.
, and
Tjioe
,
L. E.
,
1982
, “
Thermal Performance Study of Two-Pass Solar Air Heaters
,”
Sol. Energy
,
28
(
5
), pp.
363
370
.
24.
Hegazy
,
A. A.
,
2000
, “
Performance of Flat Plate Solar Air Heaters With Optimum Channel Geometry for Constant/Variable Flow Operation
,”
Energy Convers. Manage.
,
41
(
4
), pp.
401
417
.
25.
El-Sebaii
,
A. A.
,
Aboul-Enein
,
S.
,
Ramadan
,
M. R. I.
,
Shalaby
,
S. M.
, and
Moharram
,
B. M.
,
2011
, “
Investigation of Thermal Performance Of-Double Pass-Flat and v-Corrugated Plate Solar Air Heaters
,”
Energy
,
36
(
2
), pp.
1076
1086
.
26.
González
,
S. M.
,
Larsen
,
S. F.
,
Hernández
,
A.
, and
Lesino
,
G.
,
2014
, “
Thermal Evaluation and Modeling of a Double-Pass Solar Collector for Air Heating
,”
Energy Procedia
,
57
, pp.
2275
2284
.
27.
Singh
,
S.
, and
Dhiman
,
P.
,
2016
, “
Thermal Performance of Double Pass Packed Bed Solar Air Heaters–A Comprehensive Review
,”
Renewable Sustainable Energy Rev.
,
53
, pp.
1010
1031
.
28.
Singh
,
S.
, and
Dhiman
,
P.
,
2016
, “
Double Duct Packed Bed Solar Air Heater Under Combined Single and Recyclic Double Air Pass
,”
ASME J. Sol. Energy Eng.
,
138
(
1
), p.
011009
.
29.
Abdullah
,
A. S.
,
Abou Al-sood
,
M. M.
,
Omara
,
Z. M.
,
Bek
,
M. A.
, and
Kabeel
,
A. E.
,
2018
, “
Performance Evaluation of a New Counter Flow Double Pass Solar Air Heater With Turbulators
,”
Sol. Energy
,
173
, pp.
398
406
.
30.
Mahmood
,
A. J.
,
2017
, “
Experimental Study of a Solar Air Heater With a New Arrangement of Transverse Longitudinal Baffles
,”
ASME J. Sol. Energy Eng.
,
139
(
3
), p.
031004
.
31.
Sivarathinamoorthy
,
H.
, and
Sureshkannan
,
G.
,
2021
, “
The Influence of Internal Heat Storage Material and Longitudinal Fins on a Double-Pass Solar Air Heater Performance
,”
ASME J. Sol. Energy Eng.
,
143
(
1
), p.
011004
.
32.
Dogra
,
S.
,
2013
, “
Effect of Artificial Roughness on Thermal and Thermohydraulic Efficiency in Rectangular Duct of a Double Pass Solar Air Heater by Using Transverse Ribs on the Absorber Plate
,”
Int. J. Mod. Eng. Res
,
3
, pp.
2271
2274
.
33.
Rawat
,
D. S.
, and
Jaurker
,
A. R.
,
2014
, “
Performance Evaluations of Two Pass Solar Air Heater Using 60 Inclined V-Shaped Ribs on Absorber Plate
,”
Int. J. Eng. Sci. Invent.
,
3
(
8
), pp.
1
10
.
34.
Ravi
,
R. K.
, and
Saini
,
R. P.
,
2016
, “
Experimental Investigation on Performance of a Double Pass Artificial Roughened Solar Air Heater Duct Having Roughness Elements of the Combination of Discrete Multi V Shaped and Staggered Ribs
,”
Energy
,
116
, pp.
507
516
.
35.
Gabhane
,
M. G.
, and
Kanase-Patil
,
A. B.
,
2017
, “
Experimental Analysis of Double Flow Solar Air Heater With Multiple C Shape Roughness
,”
Sol. Energy
,
155
, pp.
1411
1416
.
36.
Sharma
,
A.
,
Bharadwaj
,
G.
, and
Varun
,
2017
, “
Heat Transfer and Friction Factor Correlation Development for Double-Pass Solar Air Heater Having V-Shaped Ribs as Roughness Elements
,”
Exp. Heat Transfer
,
30
(
1
), pp.
77
90
.
37.
Sivakandhan
,
C.
,
Arjunan
,
T. V.
, and
Matheswaran
,
M. M.
,
2020
, “
Thermohydraulic Performance Enhancement of a New Hybrid Duct Solar Air Heater With Inclined Rib Roughness
,”
Renewable Energy
,
147
, pp.
2345
2357
.
38.
ASHRAE
,
1977
, 93–77, “
Methods of Testing to Determine the Thermal Performance of Solar Collectors
,”
New York
.
39.
Webb
,
R. L.
,
1981
, “
Performance Evaluation Criteria for Use of Enhanced Heat Transfer Surfaces in Heat Exchanger Design
,”
Int. J. Heat Mass Transf.
,
24
(
4
), pp.
715
726
.
40.
Ong
,
K. S.
,
1995
, “
Thermal Performance of Solar Air Heaters: Mathematical Model and Solution Procedure
,”
Sol. Energy
,
55
(
2
), pp.
93
109
.
41.
Hollands
,
K. G. T.
, and
Shewen
,
E. C.
,
1981
, “
Optimization of Flow Passage Geometry for Air-Heating, Plate-Type Solar Collectors
,”
ASME J. Sol. Energy Eng.
,
103
(
4
), pp.
323
330
.
42.
Klein
,
S. A.
,
1975
, “
Calculation of Flat-Plate Collector Loss Coefficients
,”
Sol. Energy
,
17
(
1
), pp.
79
80
.
43.
Han
,
J. C.
,
Park
,
J. S.
, and
Lei
,
C. K.
,
1985
, “
Heat Transfer Enhancement in Channels With Turbulence Promoters
,”
ASME J. Eng. Gas Turbines Power
,
107
(
3
), pp.
628
635
.
You do not currently have access to this content.